HOLZMANN Maschinen Austria
www.holzmann-maschinen.at
Strana 23
Naftový horkovzdušný ohřívač / diesel gas burner HKD15 / HKD30T
16
TROUBLE SHOOTING
The heater is equipped with a self detecting device. By normal operation the warning lamp is
lighted. If the warning lamp becomes flashed, check the followings:
E)
If the power supply is correct as specified;
F)
If the fuel used is correct as specified;
G)
If there is something blocked the air inlet and/or hot air outlet;
H)
If the room temperature control is set too low;
I)
If the fuel tank is empty;
J)
If the ambient temperature is below 0
℃
, fuel de-icer is necessary.
After then repeat to start the heater, if problem still exists, send the heater to your dealer or pro-
fessional service.
Problem observed
Possible causes
Solution
Can not start
Wiring loose or worn out
Reconnect or replace
Control circuit board worn
out
replace
Thermostat broken
replace
No spark
Igniter cable loose or worn
out
Reconnect or replace
Improper igniter gap
Adjust to 2.5 -3.0 mm
Faulty transformer
replace
Burner starts but shuts off ab-
normally afterwards
Dirty fuel filter
Clean/replace
Dirty nozzle
Clean/replace
Dirty photocell
Clean with care
Faulty solenoid valve
replace
Unstable burning
Dirty nozzle
Clean/replace
Dirty fuel filter
Clean/replace
False air pressure
Clean air filter/clean or
replace
Check air line/replace
Check fuel line/replace
Resetting pressure
Rotor & blade
worn/replace
.
Summary of Contents for HKD15