storage  and  at  the  same  time  enter  Units  set  menu,  the  press 

”  key  t

o  change  unit  and  short  press 

“SET” key

 storage and long press 

“SET” key

 to back 

FS

” menu

 or continue long press 

“SET” key

 to back 

pressure/level reading windows. 

 

Step  7: 

Long press  “

” key in  the “AS” to 

quit  setting  interface.  The  LCD  will  display  pressure 

value. 

Note: Long press 

 key can make the terminal quit working mode to setting mode. 

 

 

5.

 

SMS configuration instructions 

5.1 SMS example 

Send: 

HPTCONFIG:PHONE=+8613812345678; APN=CMNET; IP=47.88.14.174; PORT=8008; 

SMS=1; TIME=350;

 

Reply: 

HPTCONFIG:PHONE=+8613812345678; APN=CMNET; IP=47.88.14.174; PORT=8008; 

SMS=1; TIME=350;

 

5.2 SMS configuration notes and matters needing attention 

(1) Flag bit 

The  configuration  information  must  begin  with  "HPTCONFIG:",  as  the  secret  key  configuration 

identification message; 

(2) Telephone number 

Configure  phone  numbers,  such  as  "PHONE=+8613812345678",  phone  number  configuration  length 

must be less than 16 bit word length, you can bring country region information; 

(3) Configure the SIM Card APN 

(4) Server IP address 

Configure the IP address, such as "IP=

47.88.14.174

" that supports only the IPV4 format length; 

(5) Port number 

Configure  the  IP  port  number,  such  as  "PORT=8008",  whose  length  is  less  than  or  equal  to  the  5  bit 

word length, and the range is "1-65535"; 

(6) Configure the transmitter data mode 

Configure data upload mode: 

Summary of Contents for HPT619

Page 1: ...GPRS GSM Wireless Temperature Level Measurement Terminals User Manual HPT619 HOLYKELL TECHNOLOGY CO LTD V2 4...

Page 2: ...omize Accuracy 1 Power Supply 3 6 Li ion battery or 10VDC 30VDC 24VAC external power supply IP Rating IP65 Working Temperature 25 85 Storage Temperature 25 85 Communication Frequency GSM GSM 850MHz EG...

Page 3: ...iagrams as shown in figure 1 Figure 1 2 On the back of the chart as shown in figure 2 Figure 2 4 LCD display and keys operating instructions 4 1 LCD display The LCD will display the current pressure m...

Page 4: ...e address range is 0 253 Short press key to add 1 of address short press to decrease 1 of address Finished short press SET key to save address to return or long press key to return Step 4 Short press...

Page 5: ...N CMNET IP 47 88 14 174 PORT 8008 SMS 1 TIME 350 5 2 SMS configuration notes and matters needing attention 1 Flag bit The configuration information must begin with HPTCONFIG as the secret key configur...

Page 6: ...unication between terminal and LLM server or other communications failure please check the LLM server r computer network connection LLM server software and SIM card is normal or not 3 Avoid the GSM an...

Page 7: ......

Page 8: ...2 After loading and desk display 3 Open LLM Wireless Pressure Level Temperature Monitor Software...

Page 9: ...your locally pc IP address such as below 172 16 2 129 not means Server IP Port must be the same as SMS configuration into Terminals Also support database building 5 Terminal Setting Likes Terminal Nam...

Page 10: ...Alarm setting and Liquid Density setting if use for different medium measurement Attention Above setting and configuration must done on configuration mode 6 Search historical data record...

Page 11: ...7 Search historical alarm data record...

Reviews: