Holt Integrated Circuits
22
1717 1818 1919 2020 2121 2222 2323 2424
2525 2626 2727 2828 2929 3030 3131 3232
STA1 1800
Dev0 MSG #0004. TIME = 00043416us BUS B TYPE1: RT to BC
CMD1 1FC0 --> 03-T-30-00
STA1 1800
DATA 0101 0202 0303 0404 0505 0606 0707 0808
0909 1010 1111 1212 1313 1414 1515 1616
1717 1818 1919 2020 2121 2222 2323 2424
2525 2626 2727 2828 2929 3030 3131 3232
2.
BC Transmits Major frames and Minor frames
Command ‘a’ demonstrates the BC transmitting a continuous stream of messages in a Major/Minor
frame format. To stop transmissions press ‘x’ followed by return. Only the first seven messages are
shown here. Since the RT and SMT and traffic commands were already enabled from the last demo,
press ‘a’ to execute this demo. Notice the RT to RT messages have a ‘no response’ error – this is
because RT2 has not been enabled.
> a
Dev0 MSG #0015. TIME = 00004238us BUS A TYPE0: BC to RT
CMD1 1822 --> 03-R-01-02
DATA 0005 0002
STA1 1800
Dev0 MSG #0016. TIME = 00004286us BUS A TYPE2: RT to RT
CMD1 182A --> 03-R-01-10
CMD2 0C2A --> 01-T-01-10
ERROR: NORES
Dev0 MSG #0017. TIME = 00004352us BUS A TYPE2: RT to RT
CMD1 182A --> 03-R-01-10
CMD2 0C2A --> 01-T-01-10
ERROR: NORES
Dev0 MSG #0018. TIME = 00004416us BUS B TYPE2: RT to RT
CMD1 182A --> 03-R-01-10
CMD2 0C2A --> 01-T-01-10
ERROR: NORES
Dev0 MSG #0019. TIME = 00104176us BUS A TYPE0: BC to RT
CMD1 1822 --> 03-R-01-02
DATA 0005 0002
Summary of Contents for ADK-2130
Page 1: ...QSG 2130mPCIe_Win10_New 06 20 A ADK 2130mPCIe Windows 10 Quick Start Guide June 15 2020...
Page 11: ...Holt Integrated Circuits 11 The Windows Driver installer pops up click Next...
Page 28: ...Holt Integrated Circuits 28 20 Pin NAME DESCRIPTION 20 Logic GND...