background image

Viking C-2000B and Essex CM265 Wiring

Contact Closure for Gate Operation 

NOTE 1: Remove the jumper wire & MOVs from left side terminal strip. Wire right side terminal strip “color for color”.

TYPE 1.1.0.3-RF

Page 3

To Door Phone 2

To Door Phone 3

To Door Phone 4

Holovision Faceplate

with Keypad

VIKING

c

Model C-2000B

1 2 3 4 5  6 7  8 9 10  11 12  13 14 15  16 17 18 19 20  21 22 23 24 25  26 27 28 29 30 31 32

E

A

R

T

H

 G

N

D

P

H

O

N

E

 L

IN

E

 I

N

P

U

T

LI

N

E

 O

U

T

 T

O

 P

H

O

N

E

S

E

N

T

R

Y

 P

H

O

N

E

 1

D

O

O

R

 S

T

R

IK

E

 1

E

N

T

R

Y

 P

H

O

N

E

 2

D

O

O

R

 S

T

R

IK

E

 2

E

N

T

R

Y

 P

H

O

N

E

 3

D

O

O

R

 S

T

R

IK

E

 3

E

N

T

R

Y

 P

H

O

N

E

 4

D

O

O

R

 S

T

R

IK

E

 4

D

O

O

R

B

E

LL

 S

W

IT

C

H

/A

U

X

 I

N

P

U

T

A

U

X

 C

O

N

TA

C

T

 O

U

T

P

U

T

1    2   3   4   5   6   7   8   9  10   11 12 13 14 15   16 17 18 19 20   21 22 23 24 25  26 27  28 29 30 31 32

O

N

 

   

   

  4

   

 5

 

A

N

A

LO

G

 S

TA

T

IO

N

 I

N

P

U

T

13.8
VAC

1.25A

House

Telephones

Essex Model 265

NC 2
NO 2

COM 2

NC 1
NO 1

COM 1

DC

OUT

AC

IN

R

em

ot

e

M

on

ito

r

Earth

16.5
VAC

22

/1

E

ss

ex

 K

ey

pa

C

ab

le

“OPEN”

Terminals

on Gate

Motor

Summary of Contents for Viking C-2000B

Page 1: ...ONS 501 E Goetz Ave Santa Ana Ca 92707 www eholovision com Ph 714 434 6904 Fax 800 362 0002 HOLOVISION 101 VIK 107 VIK 201 VIK 203 VIK 301 VIK 302 VIK Holovision Face Plate shown with E 10 installed V...

Page 2: ...e 2 TYPE 1 1 0 3 RF VIKINGc Model C 2000B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 EARTH GND PHONE LINE INPUT LINE OUT TO PHONES ENTRY PHONE 1 DOOR STRIKE...

Page 3: ...17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 EARTH GND PHONE LINE INPUT LINE OUT TO PHONES ENTRY PHONE 1 DOOR STRIKE 1 ENTRY PHONE 2 DOOR STRIKE 2 ENTRY PHONE 3 DOOR STRIKE 3 ENTRY PHONE 4 DOOR ST...

Page 4: ...uded for details ON ON ON 1 2 3 ON ON ON 1 2 3 Spkr Vol Mic Vol Holovision recommends the default settings on the dip switches See the E 10 manual for more information E 10 The SPKR VOL pot can be adj...

Page 5: ...ES 3 Double beep indicates accessing the programming mode 4 You can now program the C 2000A The features covered in this manual are Maximum Doorphone Ring Count and Door Strike Activation Time For inf...

Page 6: ...5 Latch CCTV Doorbell Relay 1 Relay 2 Step Action 2 Relay 1 and 2 activate and latch Code Relay 1 Relay 2 Open Latch Open Latch Master Code No No No No Code 1 2 Yes Yes No No Code 3 4 5 No No Yes Yes...

Page 7: ...conds of Step 3 5 Enter Master Code 6 Wait 5 seconds for 3 beeps to confirm new Master Code Set Master Code Step Action 1 Enter Master Code 2 Enter 111 3 beeps 3 Enter User Code 1 4 Wait 5 seconds for...

Page 8: ...reset beeps 4 Wait 5 seconds for 3 reset beeps Delete Any Code Step Action Note User codes can be 3 to 8 digits 1 Enter any User Code 1 5 2 Enter 7 This will cause the relay to latch subject to the j...

Page 9: ...ess Program switch keypad will beep 4 times 2 Enter 1115 3 beeps 3 Enter 1 for every 1 second latch time and 5 for every 5 seconds Examples 6 seconds 5 1 8 seconds 5 1 1 1 12 seconds 5 5 1 1 4 Wait 5...

Page 10: ...www eholovision com 501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002...

Reviews: