HOLOVISION’s Programming Notes
Doorstrike Activation Time -
Generally the default setting of 1/2 sec is fine. The momentary contact can open a motorized gate, or activate the relay on the
“S-12” keypad. For other keypad types this will be changed.
Doorbell Mode (*1)-
phones will not ring when doorbell is pushed. This is useful when conventional door chimes are desired. In order to use this feature, the
Auxiliary Contacts must be programmed. (see above)
Custom Ring Mode (*2)-
Distinguishes doorbox ring from CO ring when connected to KSU.
CCTV Video Control Mode (*8)-
The C-1000B can switch 2 CCTV cameras, displaying the camera at the doorbox which initiates the call. This mode cannot
be used when the “Auxiliary Contacts” are being used.
Disable Special Modes (*0)
-
Use this command to disable (clear) all special modes programmed.
REFER TO C-1000B MANUAL FOR MORE INFORMATION ON THESE, AND OTHER MODES OF OPERATION.
`
1
Slide the TALK BATTERY switch to the OFF position.
2
Move DIP SWITCH 2 from ON to OFF.
3
Re-connect the PHONE LINE INPUT and LINE OUT TO PHONES.
Return to normal use mode
Step
Action
OPERATION OF C-1000B
ANSWER A CALL FROM DOORBOX
When the phones ring, pick up a phone to be connected to the visitor. When the C-1000B controller is used, you will
hear a beep tone when the phone is answered - one beep for doorbox 1, and 2 beeps for doorbox 2
.
PLACING CO LINE CALLS ON HOLD (CALL WAITING)
If a phone call is in progress, and a door box is activated, a single or double “call waiting “ tone will be heard. To place the call in
progress on hold and speak to the visitor, push
#
. When you want to return to the original phone call, push
#
.
ACTIVATING A DOORSTRIKE OR OPENING A GATE
To open the gate, you must first be connected to the doorbox. Push
.You will then hear a confirmation tone, and the relay will be
activated for the programmed time. If a call was already in progress, pressing will open the gate, and return the system to the
original phone call.
LATCH / UNLATCH A GATE
To use this feature, you must first be connected to the doorbox.
Latch relay 1 or 2
1
Unlatch relay 1 or 2
0
**
*
*
**
Page 4
TYPE 6.4.0.5-RF