background image

Programming the Essex Keypad

Note

: If the User ID, or User Code/PIN has not been assigned, you will hear one long beep 

when #  is entered.  

Reset Keypad to Factory Defaults--- This is not normally necessary, but can be done as follows

STEP       ACTION                                                                              BEEP          Red LED Green LED

        1            

The default Master Code is “123”

.                                                                                                                                                             

.                      This can be changed to a unique code  3 - 8 digits long.

        2            Enter 

*3 1 2 3

#

                                                                                                       Double Beep          Slow Flash         Solid

        3            Enter 

#

                                                                                                                   Double Beep          Slow Flash

Slow Flash

        4            Enter the desired activation time in 

Seconds

followed by 

#

                                     Triple Beep            Slow Flash

Solid

        5            Enter 

* *

to exit

        6            Example:
                      

2 # 10 # 

* *

(10 second activation time)

Setting Main Relay Opening Time

STEP       ACTION                                                                             BEEP          Red LED

Green LED

        1            Remove power 

        2            Jumper the “CONFIG”  pins on the rear of the keypad

        3            Apply 12 VDC power to red and black wires ONLY                                                   Quadruple Beep       Flash                      Solid

        5            Enter 

0 0 9 9 

#

                                                                                                         Double Beep             Flash

3 Sec Flash

        6            WAIT about 4 seconds                                                                                               Quadruple Beep        Flash                      Solid

        7            Enter 

9 9 

#

                                                                                                                Triple Beep                Flash 

Solid

        8            Remove power

        9            Remove “CONFIG” jumper

       10           Reapply  power

Page 8

TYPE 6.2.0.7-RF

Summary of Contents for 400-S12-TES2

Page 1: ...y an swering any of the ringing phones in the House TES2 is a 2 door system front door back door Access Control Essex stand alone 12 button keypad 1 relay plus 2 grounding outputs external relays requ...

Page 2: ...for DC voltage to strike Remote Bypass Button Gate Strike DC Out for Strike 12 Volt 12 Volt No Ring Jumper House Telephones NOTE Voltage from telephones is not necessary for the system to work See not...

Page 3: ...ecessary for the system to work See note No CO operation The connection between the main board and the speaker board is polarity sensitive CO Line In To House Phones Door 2 Door 1 T1 R1 T2 R2 No Co Ju...

Page 4: ...hones is not necessary for the system to work See note No CO operation The connection between the main board and the speaker board is polarity sensitive CO Line In To House Phones Door 2 Door 1 T1 R1...

Page 5: ...Solid 3 Enter 1 Double Beep Fast Flash Slow Flash 4 Enter new master code followed by Triple Beep Fast Flash Solid 5 Enter Double Beep 6 EXAMPLE old code is 123 new code is 456 3 1 2 3 1 4 5 6 Set Ma...

Page 6: ...Triple Beep Slow Flash Slow Flash 10 Enter Double Beep X 2 Set User Codes STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step Master Code 123 is used as an example 2 Ente...

Page 7: ...e programming Triple Beep Slow Flash Slow Flash 7 Enter Double Beep X 2 Deleting User Codes using User Code PIN STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step In thi...

Page 8: ...Double Beep Slow Flash Slow Flash 4 Enter the desired activation time in Seconds followed by Triple Beep Slow Flash Solid 5 Enter to exit 6 Example 2 10 10 second activation time Setting Main Relay O...

Page 9: ...on would be used if the homeowners used cell phone only no house phone line In this case several phones would be required throughout the house These phones would be used only for answering door phone...

Page 10: ...ilt in call waiting If the house phone is in use when the door button is pushed the caller will receive a call waiting tone To answer the door call simply flash to answer the door call and flash again...