4.  OPTIONS OR ACCESSORIES

The following options or accessories may be present on your
installation.

4.1  Visor Installation and Maintenance. 

  When

installed, the visor limits the vertical spread of emitted light.

4.1.1 

 Attach the clips to the shield, one in the center and one on

each corner at approximately the location of the holes.  The shield
goes into the narrow side of the clip.  See Figure 3.

4.1.2

  Fasten the shield with the clips to the door assembly.  A

small screwdriver can be used to spread the leg of clips to start
them over the cast rib on the door.

NOTE

Three 3/16" diameter holes in shield can be used as a template if
the installer chooses to drill holes through the casting rib and fasten
the shield to the door with screws (not included).  Screws are
recommended in high wind and rough service areas.

4.1.3

  Clean accumulated dust and dirt from visor when relamping.

4.2  Wire Guard Installation and Maintenance.

 When

installed, the wire guard helps protect the tempered glass lens from
damage.

4.2.1

  Loosen the captive door screws.  See Figure 4.

4.2.2 

 Slide the mounting loops in the wire guard over all four

screws.

4.2.3  

Tighten captive door  screws to 55 in. lbs.  torque.  This is

required for watertight door seal.

5.  Limited Warranty and Limitation of Liability

The Holophane limited warranty and limitation of liability is published
in the "Terms and Conditions" section of the current Holophane
buyer's guide, and is available from your local Holophane sales
representative.

Figure 3

GR423

Figure 4

GR424

Acuity Lighting Group, Inc.

214 Oakwood Ave., Newark, OH 43055

IM-63-C  7/02 

 

2002 Acuity Lighting Group Inc.

Visit our web site at www.holophane.com

Printed in USA

®