IM-30-G
g. Tag and disconnect common and line leads.
h. Remove and retain component mounting hardware.
i. Tag associated electrical leads, and remove involved component.
j. Install new component using existing mounting hardware.
k. Make electrical connections in accordance with tags and
approved wiring practices.
l. Reconnect incoming supply leads.
m. Replace access cover.
n. Replace socket plate and gasket using the existing screws.
o. Reinstall the lamp.
p. Wipe off gasket area with clean, dry cloth to ensure a proper seal.
q. Install refractor onto electrical housing. Verify the optics are
oriented the same as previously installed. Verify that the lip on the
refractor slips past the optics mounting clips on the electrical
housing. See Figures 2 and 3. Tighten the optics mounting clip
screws.
r. Energize the fixture and check for proper operation.
4. ACCESSORIES
4.1 GV1A73 Pole Top Adaptor for use with
Arcadian, Fluted and Octagonal Styles.
Refer to Figure 6.
4.1.1
Place and level pole top adapter on the pole. Alternate
tightening of the six set screws will assist in centering the adapter on
the tenon. Tighten the four set screws 25 to 30 inch pounds.
4.1.2
Install the luminaire.
Figure 6
GR1044
4. LIMITED WARRANTY AND
LIMITATION OF LIABILITY
The Holophane limited warranty and limitation of liability is published
in the "Terms and Conditions" section of the current Holophane
buyer’s guide, and is available from your local Holophane sales
representative.
®
Acuity Brands Lighting, Inc.
3825 Columbus Rd SW, Granville, OH 43023
IM-30-F, 8/03 ©2010 Acuity Lighting Group Inc.
All Rights Reserved
Visit our web site at
www.holophane.com
Printed in USA
DISCONTINUED