IM-30-G
b. Place and level electrical housing on pole. Alternate tightening of
the four set screws will assist in centering the ballast housing on
the tenon. Tighten the four set screws 25 to 30 inch pounds.
c. Connect incoming ground wire to ground wire attached to the
inside bottom of wiring chamber. Connect incoming common wire
to wire marked COM which is attached to the ballast assembly. If
a single voltage ballast, check the voltage number on the
remaining wire to verify the ballast voltage. Connect this wire to
the incoming supply line. Note: Lead may need to be stripped. If
a multi tap ballast, find the correct voltage marked on one of the
remaining wires and make the connection. Carefully place
connections in wiring chamber for future access.
d. Install the proper lamp type. Tighten the lamp carefully but
securely.
e. Wipe the gasket and seal area with a clean, dry cloth to ensure a
proper seal.
Figure 1
GR178C
Figure 2
Glass Refractor must be oriented for correct lighting distribution.
Blue dot on inside of glass refractor is street side.
GR847
OPTICS ORIENTATION NOTES
Some of the fixtures in this series are equipped with optical
components that produce distributions of light that are not symmetric
and are intended to be aimed by orienting the prismatic glass
refractor a specific direction. The “Street Side” marking on the
refractor should be pointed toward the street.
f. Install glass onto electrical housing. Verify that the lip on the glass
slips past the optics mounting clips on the electrical housing. See
Figures 2 and 3. Tighten the optics mounting clip screws.
g. Energize the fixture and check for proper operation.
Figure 3
GR1033
2.2.2 Installation for Simple and Leaf Style.
Refer to Figure 2, 3, 4, and 5.
a. Remove access cover and gasket on electrical housing to provide
access to wiring chamber.
b. Wires in pole or tenon should enter the electrical housing via the
opening provided in the bottom of the wiring chamber.
Figure 4
GR179C
DISCONTINUED