 IM-274-E 

 

 

Brush off loose dirt and debris. The optical 
assembly may be cleaned with water and 
detergent to return it to maximum optical 
performance. Dry the assembly with a clean 
cloth. 

 

Check the exterior of the housing for evidence of 
damage or potentially hazardous conditions. 

 

Remove the lamp when cool and replace with the 
exact type shown on the luminaire ballast 
housing.   

 

Restore power to the luminaire, the lamp should 
strike within 1-2 minutes. 

 
2.4.2 Ballast 

Replacement 

 

There are no user serviceable parts or fuses on 
the ballast 

 

Disconnect electrical power to the fixture. 

 

REMOVE THE FIXTURE TO A HORIZONTAL WORK 
SURFACE BEFORE ATTEMPTING TO REMOVE ANY 
SCREWS THAT SECURE THE HOUSING AND OPTIC 
ASSEMBLY TOGETHER. FAILURE TO DO SO MAY 
RESULT IN INJURY OR DEATH OR SIGNIFICANT 
PROPERTY DAMAGE.

 

 

 

To separate the electrical assembly from the 
optic assembly, use 3/8 socket driver to unscrew 
two screws from the electrical housing assembly. 

 

For standard construction see 

Figure 5.  

For EA option construction see 

Figure 7.

  

 

Carefully disconnect the leads between the optic 
assembly and electrical assembly 

 

Disconnect all leads connected to the ballast 

  Loosen four screws holding the ballast to the 

housing 

  To re-install the ballast to the unit reverse 

previous steps and make sure the ballast is 
installed tightly to the wall. 

 

 
2.4.3 

Optical Component Replacement 

 

Disconnect electrical power to the fixture. 

REMOVE THE FIXTURE TO A HORIZONTAL WORK 
SURFACE BEFORE ATTEMPTING TO REMOVE ANY 
SCREWS THAT SECURE THE HOUSING AND OPTIC 
ASSEMBLY TOGETHER. FAILURE TO DO SO MAY 
RESULT IN INJURY OR DEATH OR SIGNIFICANT 
PROPERTY DAMAGE.

 

 

Check, the exterior of the housing, arched rods, 
socket, top and bottom rings for evidence of 
damaged or potentially hazardous conditions. 

  To separate the optic from the electrical 

assembly, use 3/8 socket driver to unscrew three 
screws from the bottom ring, see 

Figure 6.

 

 

 

Remove damaged optic from the assembly. 

 

Position the replacement optic into bottom ring. 

  Set the electrical assembly on the top of the 

replacement optic. 

 

Install three arched rod ends to top ring, 

 

Install three arched rods to bottom ring. 

 

Install screws (Apply torque 55-65 inch pound) 
onto bottom ring nuts and evenly tighten. 

  Install lamp of proper wattage as specified on 

luminiare. 

Operation of the Electronic Ballast 

3.1 Luminaire Operation 

 

Lamp Starting 

When the is unit powered, the lamp should strike 
within 1-2 minutes.  

3.2 Dimming  

The Enduratron luminaires can be dimmed to 
50% power with the application of a 0-10Vdc 
dimming signal applied to the dimming terminals 
on the top of the luminaire.  If no dimming signal 
is connected to the dimming terminals, the 
luminaires will operate continuously at 100% 
power. 
The dimming operation of electronic ballast is 
suspended for the first 20 minutes of operation of 
the luminaire.  The lamp will operate at 100% 
power during this period. This delay is required to 
stabilize the lamp thermally to permit good color 
control and lamp stability thru life as prescribed 
by the lamp manufactures. 

 