 IM-274-E 

 

1    INTRODUCTION 
 
1.1 Product Description

 

The Enduratron lighting fixture has been listed to 
applicable U.S. and Canadian safety standards 
by Underwriters Laboratories Inc. 
 

 

1.2  Alternate Information Sources

:

 

Holophane 

Field Service Department 

P.O. Box 3004 

Newark, OH 43058-3004 

(866) 759-1577 

 

2 INSTALLATION 

 

This fixture should be installed in mounted 
accordance with local codes and regulations. 

 

2.1  Tools and Materials Required

 

TABLE 1.  Installation Tools and Materials 

 

DESCRIPTION use 

Flat head screwdriver 

Open wire way cover 

3/8” socket set  

Electrical component 
replacement  

 

2.2 Unit installation

 

 

2.2.1 

Unit With Hook

 

 

Remove the unit from carton and hang it by its 
hook on appropriate loop or eyebolt secured to 
building structure.  Secure the fixtures to the loop 
or eyebolt by tightening screw until screw 
touches hook as shown in 

Figure 1

 

Figure 1 

SCREW

LOOP OR

EYEBOLT

HOOK

 

 
 

GR1790 

 

 

PHCB, Cord and Plug, or Cord Only Unit With 
Hook Installation  

o

 

If cord only, attach appropriate connector in 
accordance with appropriate local codes and 
regulations. 

o

 

Connect twist lock plug to outlet device in 
vicinity of fixture.   

 

 

Holoflex Unit With Hook Installation  

o

 

Connect Holoflex plug to Holoflex wiring 
system port in vicinity of fixture. 

 

2.2.2 

Pendant Mount Installation 

 

Apply thread locking material to ¾-14 NPT hook 
or pipe threads.

 

 

Thread male hook or pipe at least 5 full turns into 
housing threaded entry until secure.

 

WARNING 

THE INSTALLER MUST APPLY THREAD 
LOCKING MATERIAL TO THE PIPE ENTRY 
THREADS BEFORE INSTALLING INTO 
HOUSING.  FAILURE TO APPLY A THREAD 
LOCKING MATERIAL TO THE THREAD CAN 
RESULT IN INJURY OR DEATH OR 
SIGNIFICANT PROPERTY DAMAGE.

 

2.2.3 

Wiring the unit: 

 

To open wire way cover, loosen the two screws 
holding the cover until it is free to turn.

 

  Turn the cover counter-clockwise at 90 degrees 

see 

Figure 2

 

  Route the supply leads through pipe entry and 

through wire way opening and use wire nuts to 
connect black to black, white to white and green 
to green as shown on 

Figure 2

.

 

 

2.2.4 

Installing The Lamp Enclosed Unit 

  Open enclosed door carefully by releasing the 

two clips holding the door shut.  Holding the door, 
gently let the door swing to a vertical position and 
let hang while lamping.  Install proper lamp type 
and tighten lamp securely into socket.

 

 

Energize the luminaire, lamp should strike within 
1-2 minutes. 

 

Reviews: