Charging the battery pack
•
Read the instructions of the battery charger before you charge the battery pack.
•
Only use one of the prescribed Holmatro battery chargers to charge the battery pack.
•
Best results and longest life of the battery pack are achieved when the battery pack is charged in a
dry environment at a temperature between 18 °C and 24 °C (64 °F and 75 °F).
•
The SOC indicator on the battery pack shows the state of charge of the battery pack.
•
The maximum capacity of the battery pack is achieved when it has been charged and discharged
some times.
•
Always charge the battery pack, also if it has been used for a short time.
•
The battery pack can stay connected to the battery charger for an indefinite period of time, because
it is protected against overcharging.
5.3
Installing the battery pack
Put the battery pack in the battery pack fitting / adapter fitting until the battery pack locks.
5.4
Connecting to an external power source
See Fig. 4.
Apart from using the battery pack, the tool can also be connected to the mains by the special mains
connector. Use only the original mains connector for this purpose.
•
Slide the adapter of the mains connector in the battery pack fitting / adapter fitting until the battery
pack lock snaps tight.
•
Insert the plug of the mains connector into the appropriate power outlet.
5.5
Starting the tool
•
Push the on/off switch of the battery to start the tool. The LEDs for the temperature, State of Charge
and the LEDs of the tool will come on.
•
The tool operates if the deadman's handle is turned to position
or
.
5.6
Operate the deadman’s handle
The deadman's handle is used to determine the movement of the plunger(s). If the deadman's handle is
released, it returns automatically to the neutral position and stops the hydraulic pump. The tool stops.
In the initial movement of the deadman’s handle the motor operates slowly. Movement of the tool will be
slow for maximum control. When the deadman’s handle is rotated further the motor will operate at
maximum speed.
Pressure is built up in the tool. Return oil from the tool flows back to the pump without pressure.
NOTICE
When the battery pack is not in use, it is advised to keep it connected to the battery charger
(connected to a power source) at all times. When the battery pack is full, the battery charger
automatically switches on and off at regular intervals to keep the battery level at 100%.
After deep discharge of the battery pack, charge the battery pack for 24 hours. If the battery
pack is not completely charged after 24 hours, contact your local Holmatro dealer.
NOTICE
When the tool is not used for 10 minutes the battery pack will stop. Push the on/off switch to
start the tool again.