![Holmatro HMC 8 U Manual Download Page 33](http://html1.mh-extra.com/html/holmatro/hmc-8-u/hmc-8-u_manual_2145838033.webp)
EN
HMC
916.269.264_008
33
Refer to Fig. 11.
-
Extend the plunger until the spring collet (1) is just visible.
-
Remove the spring collet with a punch.
-
Fit the new blade (2) using the spring collet.
•
Replace a damaged fixed blade:
Refer to Fig. 12.
-
Release the cap screw (1).
-
Place the new blade (2) in the recess.
-
Install cap screw (1) and slightly tighten it.
-
Connect the cutter to a hydraulic pump.
-
Extend the moveable blade until it pushes against the fixed blade at full pressure.
-
Depressurize the pump
•
Apply grease to the blades.
8.5
Yearly dealer maintenance
We recommend having the equipment inspected, checked, set and tested once a year by a Holmatro
Certified Technician who has the appropriate knowledge and the necessary tools (see also section 1.7).
The Holmatro dealer can organize the yearly maintenance for you on a contract basis.
8.6
Long term storage
•
Ensure that the equipment is completely depressurized.
•
Store the equipment in a dry, well-ventilated area. Use additional preservatives on the external steel
parts.
9
Decommissioning/Recycling
At the end of its service life the equipment can be scrapped and recycled.
•
Make sure that the equipment is put out of order to avoid any use.
•
Check that the equipment does not contain any pressurized components.
•
Recycle the various materials used in the equipment such as steel, aluminium, NBR (Nitrile
Butadiene Rubber) and plastic.
•
Collect all dangerous substances separately and dispose of them in an environmentally responsible
way.
•
Consult the Holmatro dealer about recycling.
CAUTION
Extending the plunger too far results in damage of the spring in the cylinder.
Summary of Contents for HMC 8 U
Page 4: ...4 916 269 264_008 HMC Fig 3 1 9 2 8 8 6 4 3 3 8 5 4 8 5 7 3 10...
Page 186: ...ZH 186 916 269 264_008 HMC 1 1 1 1 2 1 3 i 1 4 1 5 1 5 1 1 6 1 7...
Page 187: ...ZH HMC 916 269 264_008 187 1 8 CE 2 2 1 2 2 1 i A 920 299 567 B 920 299 572...
Page 188: ...ZH 188 916 269 264_008 HMC 2 3 2 4 2 5 2 6 IEN ISO 12100 C CE...
Page 192: ...ZH 192 916 269 264_008 HMC 5 1 3 5 2 5 2 1 5 2 2 4 5 2 3 5 5 3 5 3 1 5 3 2 6 0 0...
Page 193: ...ZH HMC 916 269 264_008 193 5 3 3 7 5 4 5 4 1 5 4 2 8 5 4 3 9 1 2 3 4 0 0...
Page 195: ...ZH HMC 916 269 264_008 195 7 7 1 7 2 i 7 3 i 7 4 i 8 8 1...
Page 198: ...ZH 198 916 269 264_008 HMC 8 5 1 7 8 6 9 NBR...
Page 199: ...HMC 916 269 264_008 199 i Fig 4 Fig 5 Fig 6 Fig 7 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4...
Page 200: ...200 916 269 264_008 HMC Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 1 2 3 4 1 2 3 4 2 1 2 1 2 1...