13
8. Troubleshooting
8.1 The quick-action couplings cannot be connected.
1
Check tool control handle
position
Handle in open or
close position
Release control handle
to neutral position
Control handle in neutral
2
Twin-line
: Check for pressure in
the hose.
---------------------------------------
Core
:
Check for pressure in the
hose.
Hose pressurized, but
not pre-connected to
pump/tool.
--------------------------
Release pressure in
hose using Pressure
Relief Device (PRD)
Hose pressure relieved
3
Twin-line
: Check for pressure in
the tool.
---------------------------------------
Core™
: Check for pressure in
the tool.
Tool pressurized, but
not pre- connected to
pressure or return
hoseline.
--------------------------
Tool pressurized, but
not pre- connected to
hoseline
Release pressure in
tool using PRD
----------------------
Release pressure in
tool using PRD
Tool pressure relieved
Pump pressure relieved(Twin-
line) or pump not pressurized
(Core™)
5
Check the coupling locking
sleeve location or dirt in coupler
Incorrect position or
dirt in coupler
Release locking
sleeve. Clean coupler
Locking ring released/Coupler
clean
6
Consult your Dealer
4
Twin-line
: Check for pressure in
the pump.
---------------------------------------
Core™
:
Check for pressure in
the pump.
Pump pressurized, but
not pre-connected to
hose.
--------------------------
Pump pressurized but
not pre-connected to
hose
Release pressure at
pump using
Operation/Release
handle.
----------------------
Turn off pump &
Consult your Dealer
Summary of Contents for CORE XR 4360 RAM
Page 1: ...XR 4360 RAM Owner s Manual 918 269 303 001...
Page 20: ...20...