45
Progressive TBI Enable/Disable:
This should be selected if using a TBI throttle body with progressive throttle linkage. All 4 BBL
TERMINATOR™ TBI systems do NOT have progressive linkage, so this should not be checked. This will NOT be shown if you have
selected a MPFI application.
TBI Secondary Blend:
If using a TBI with progressive linkage, this value is used to start the ramp-in of the secondary fuel injectors as the
rear throttle plates open. Enter the TPS when the rear throttle plates start to open. This is typically 36% for a Holley throttle body unit.
The “Check for Progressive Throttle Linkage” must be checked for this box to be enabled. This will NOT be shown if you have selected a
MPFI application
NOTE:
Holley
MPFI and TERMINATOR™ injector size/flow is calculated at 43 PSI.
Figure 114
Figure 115
Figure 116
33.1.3 Ignition Setup
There are two parameters that are adjustable in the IGNITION SETUP. Ignition input type and engine rev limiter.
REV LIMIT
–
The rev limiter is only enabled when using a computer controlled small cap GM HEI. It is an ignition-only rev limiter.
It will not shut fuel off. Enter a value for which you’d like the rev limiter to start.
Figure 117 Figure 118
NOTE:
MPFI
and TERMINATOR™ injector size/flow is calculated at 43 PSI. TBI injector size/flow is calculated at 21 PSI.