Holland Green Science 10311001 User Manual Download Page 9

 

 

User Manual 

 

 

3.2  Proper Use  

 

The Zephyrus series are designed for non-residential use e.g. in schools, laboratories or 
factories and to be used in conjunction only with accessories recommended within this manual 
and by the manufacturer 

 

3.3  After Sales Support 

If problems are encountered or technical assistance support is required, when installing or using 
the instrument, please immediately contact the service department. 

The company may provide 

technical assistance and information regarding the instrument or equipment or service without 
charge at its sole discretion. Buyer assumes sole responsibility for any reliance on or use of 
such assistance and information, and the company makes no warranty thereon. 

Upon contact the following information is required to be provided: 

  Product serial number (located on rear panel instrument nameplate) 

  Warranty card 

  Description of issue or problem (i.e., software or hardware) 

  Method and or operating steps you have undertaken towards resolution. 

  Your contact details inclusive of telephone number and email address. 

 

For claims under the warranty please contact your local supplier. You may also send the 
instrument directly to manufacturer, enclosing the invoice copy and by giving reasons for the 
claim. Prior to returning any pump for service or maintenance, it is mandatory to provide 
information if the pump has been contaminated and if so, what pollutants or hazardous 
substances may be existing within the pump. Without this required statement provided in 
advance to the receiving service team, the pump will be declined by receiving and returned to 
the sender. 

 

 

Summary of Contents for 10311001

Page 1: ...10311001 10311002 10311003 Zephyrus Series Diaphragm Pump User Manual...

Page 2: ...Introduction 8 3 1 Main Features 8 3 2 Proper Use 9 IV Zephyrus Series Diaphragm Pump Overview 10 V Technical Specifications 11 VI Standards and Conformity 12 VII Inspection 13 7 1 Packing List 13 VII...

Page 3: ...sentations of the potential dangers from the instrument or equipment Buyer is solely responsible for conducting any research necessary to learn the hazards involved for any of its intended uses of the...

Page 4: ...e fault or negligence of or by Buyer iv use of the Product in a manner for which they were not designed v causes external to the Product such as but not limited to power failure or electrical power su...

Page 5: ...NTAL MISUSE OF THE PRODUCTS USE WITH INAPPROPRIATE REAGENTS OR CONSUMABLES DAMAGE CAUSED BY DISASTER REPAIR OR MODIFICATIONS DONE BY ANYONE OTHER THAN THE COMPANY THE COMPANY DOES NOT WARRANT THAT THE...

Page 6: ...r intends and agrees that such software products are being licensed and not sold and that the words purchase sell or similar or derivative words are understood and agreed to mean license and that the...

Page 7: ...Please fully read and understand all the user manual instructions prior operation 8 When unplugging the power plug do not pull on the power cord directly 9 Prior to all the below activities the instru...

Page 8: ...signed PTFE coated diaphragm and pump head joint fixtures and pipelines Additionally all electrical components and chassis are also solid PTFE or PTFE coated 3 1 2 Non Polluting and Maintenance Free T...

Page 9: ...ty thereon Upon contact the following information is required to be provided Product serial number located on rear panel instrument nameplate Warranty card Description of issue or problem i e software...

Page 10: ...4 3 Zephyrus Max Diaphragm Pump 1 Suction Side 2 Discharge Side 3 Working Pump Body 4 Connection Pipe 5 Power Switch 1 2 3 4 5 1 2 3 4 5 1 2 3 5 4 1 Suction Side 2 Discharge Side 3 Working Pump Body...

Page 11: ...ad Type Ultimate Vacuum Two Stage Pump Ultimate Vacuum 6 8 mbar Maximum Operating Pressure 1 bar Maximum Flow 40 L min 65 L min 130L min Interface Specification 10 mm 12 mm Medium and Ambient Temperat...

Page 12: ...nual 12 VI Standards and Conformity Construction in Accordance with the following Safety Standards EN 61010 1 CSA C22 2 61010 1 12 2012 Construction in Accordance with the following EMC Standards EN 6...

Page 13: ...iaphragm pump and place it onto a clean level surface bench Check the instrument and accessories against the below Packing List If the instrument or accessories are found to be incorrect or the access...

Page 14: ...hould only be operated in a well ventilated area to ensure sufficient cooling air is available The required AC line voltage and power usage are listed on the pump s nameplate Make sure that the extern...

Page 15: ...completely empty c This equipment is not considered safe for use in areas that are Hazard Free This is due to the potential for fire and or explosion if volatile chemicals are in use d It is not reco...

Page 16: ...the filter is blocked Check all valves and filter connections Excess condensation in pump head After the pump is relieved of vacuum continue to run the pump for 5 minutes and restart process Composite...

Page 17: ...operations The external surface of the Zephyrus series diaphragm pump should be cleaned after the power is disconnected using a non abrasive cleanser If liquid or moist solids enter the instrument imm...

Reviews: