III. 

Zephyrus Series Diaphragm Pump 

– Introduction

 

 

The Zephyrus series diaphragm pump is constructed using polytetrafluoroethylene (PTFE) 
making it corrosion resistant and ideal for processing corrosive gases commonly used by 
the pharmaceutical and petrochemical industries. It is specifically designed to easily work in 
environments where suction filtration, vacuum distillation, rotary evaporation, vacuum 
concentration, centrifugal concentration, solid phase extraction, and the like are required. 

 

3.1  Main Features 

  

3.1.1 Strong Chemical Corrosion

 

Resistance 

 
The Zephyrus series corrosion-resistant pump uses a PTFE to coat all surfaces that in 
contact with the processed gas/liquids. These include the specially designed PTFE coated 
diaphragm and pump head, joint fixtures, and pipelines. Additionally, all electrical 
components and chassis are also solid PTFE or PTFE coated.  
 
 

3.1.2 Non-Polluting and Maintenance Free 

 

The Zephyrus series diaphragm pump can completely recover and separate solvents used 
in the processing, thereby eliminating environmental pollution. The Zephyrus series 
diaphragm pumps are water/oil-free dry pumps 

and are ideal for use in “clean rooms” and 

low noise environments. The pumps are designed for very low maintenance. 

 
3.1.3 Low Noise and Low Vibration 

 

The Zephyrus series diaphragm pumps use a direct drive power transmission plus a low 
noise diaphragm that operates at or below 70 decibels. 
 

 
3.1.4 Overheat Protection 

 
The Zephyrus series diaphragm pumps are equipped with thermal protection sensors that 
stop processing if excessive heating occurs. The process will automatically be restarted 
after the system cools.   

 

 

Summary of Contents for 10311001

Page 1: ...10311001 10311002 10311003 Zephyrus Series Diaphragm Pump User Manual...

Page 2: ...Introduction 8 3 1 Main Features 8 3 2 Proper Use 9 IV Zephyrus Series Diaphragm Pump Overview 10 V Technical Specifications 11 VI Standards and Conformity 12 VII Inspection 13 7 1 Packing List 13 VII...

Page 3: ...sentations of the potential dangers from the instrument or equipment Buyer is solely responsible for conducting any research necessary to learn the hazards involved for any of its intended uses of the...

Page 4: ...e fault or negligence of or by Buyer iv use of the Product in a manner for which they were not designed v causes external to the Product such as but not limited to power failure or electrical power su...

Page 5: ...NTAL MISUSE OF THE PRODUCTS USE WITH INAPPROPRIATE REAGENTS OR CONSUMABLES DAMAGE CAUSED BY DISASTER REPAIR OR MODIFICATIONS DONE BY ANYONE OTHER THAN THE COMPANY THE COMPANY DOES NOT WARRANT THAT THE...

Page 6: ...r intends and agrees that such software products are being licensed and not sold and that the words purchase sell or similar or derivative words are understood and agreed to mean license and that the...

Page 7: ...Please fully read and understand all the user manual instructions prior operation 8 When unplugging the power plug do not pull on the power cord directly 9 Prior to all the below activities the instru...

Page 8: ...signed PTFE coated diaphragm and pump head joint fixtures and pipelines Additionally all electrical components and chassis are also solid PTFE or PTFE coated 3 1 2 Non Polluting and Maintenance Free T...

Page 9: ...ty thereon Upon contact the following information is required to be provided Product serial number located on rear panel instrument nameplate Warranty card Description of issue or problem i e software...

Page 10: ...4 3 Zephyrus Max Diaphragm Pump 1 Suction Side 2 Discharge Side 3 Working Pump Body 4 Connection Pipe 5 Power Switch 1 2 3 4 5 1 2 3 4 5 1 2 3 5 4 1 Suction Side 2 Discharge Side 3 Working Pump Body...

Page 11: ...ad Type Ultimate Vacuum Two Stage Pump Ultimate Vacuum 6 8 mbar Maximum Operating Pressure 1 bar Maximum Flow 40 L min 65 L min 130L min Interface Specification 10 mm 12 mm Medium and Ambient Temperat...

Page 12: ...nual 12 VI Standards and Conformity Construction in Accordance with the following Safety Standards EN 61010 1 CSA C22 2 61010 1 12 2012 Construction in Accordance with the following EMC Standards EN 6...

Page 13: ...iaphragm pump and place it onto a clean level surface bench Check the instrument and accessories against the below Packing List If the instrument or accessories are found to be incorrect or the access...

Page 14: ...hould only be operated in a well ventilated area to ensure sufficient cooling air is available The required AC line voltage and power usage are listed on the pump s nameplate Make sure that the extern...

Page 15: ...completely empty c This equipment is not considered safe for use in areas that are Hazard Free This is due to the potential for fire and or explosion if volatile chemicals are in use d It is not reco...

Page 16: ...the filter is blocked Check all valves and filter connections Excess condensation in pump head After the pump is relieved of vacuum continue to run the pump for 5 minutes and restart process Composite...

Page 17: ...operations The external surface of the Zephyrus series diaphragm pump should be cleaned after the power is disconnected using a non abrasive cleanser If liquid or moist solids enter the instrument imm...

Reviews: