1. Particular Specifications 

Product Order

Model   

Input Voltage 

Power 

(KW) 

Inverter 

Capacity 

(KVA) 

  Output 

Current 

(A) 

Suitable 

Motor 

(KW) 

30002101 

HLPSV00D421A 

1

×

200-240V 50/60Hz 

0.4 

1.0 

2.5 

0.4 

30002102 

HLPSV0D7521A 

1

×

200-240V 50/60Hz 

0.75 

2.0 

4.2 

0.75 

30002103 

HLPSV01D521A 

1

×

200-240V 50/60Hz 

1.5 

2.8 

6.8 

1.5 

** 

HLPSV02D221A 

1

×

200-240V 50/60Hz 

2.2 

** 

**

 

2.2 

** 

HLPSV03D721A 

1

×

200-240V 50/60Hz 

3.7 

** 

**

 

3.7 

30002301 

HLPSV00D423A 

3

×

200-240V 50/60Hz 

0.4 

1.0 

2.5 

0.4 

30002302 

HLPSV0D7523A 

3

×

200-240V 50/60Hz 

0.75 

2.0 

4.2 

0.75 

30002303 

HLPSV01D523A 

3

×

200-240V 50/60Hz 

1.5 

2.8 

6.8 

1.5 

** 

HLPSV02D223A 

3

×

200-240V 50/60Hz 

2.2 

**

 

**

 

2.2 

** 

HLPSV03D723A 

3

×

200-240V 50/60Hz 

3.7 

**

 

**

 

3.7 

30004302 

HLPSV0D7543A 

3

×

380-480V 50/60Hz 

0.75 

2.2 

2.2 

0.75 

30004303 

HLPSV01D543A 

3

×

380-480V 50/60Hz 

1.5 

3.2 

3.7 

1.5 

30004304 

HLPSV02D243A 

3

×

380-480V 50/60Hz 

2.2 

4.0 

5.3 

2.2 

** 

HLPSV03D743A 

3

×

380-480V 50/60Hz 

3.7 

**

 

**

 

3.7 

** 

HLPSV05D543A 

3

×

380-480V 50/60Hz 

5.5 

**

 

**

 

5.5 

** 

HLPSV07D543A 

3

×

380-480V 50/60Hz 

7.5 

**

 

**

 

7.5 

**

These dimensions will be announced at a later point. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 30002101

Page 1: ...Inverter 1 HLP SV Series User s Manual...

Page 2: ...Inverter 2 Zhejiang HOLIP Electronic Technology co Ltd ADD Section C 7 F Wuchan Building NO 445 Kaixuan Road Hangzhou TEL 0571 86772676 FAX 0571 86772912 Http www holip com...

Page 3: ...Diagram 14 2 Description of Terminal Block 15 3 Basic Connection Diagram 17 4 Switches 17 5 Precautions on Wiring 18 Instruction of the LCP Digital Operator 20 1 Description of the LCP Digital Operato...

Page 4: ...ly before wiring l Do not touch any internal electrical circuit or component when the charging lamp is still on after the AC power supply is disconnected which means the inverter still has high voltag...

Page 5: ...specifications meet your order Operating voltage and KVA value l Check if there is something wrong with the inner parts wiring and circuit board l Check if each terminal is tightly locked and if ther...

Page 6: ...nverter 6 Voltage Rating 21 1 Phase AC 220V 23 3 Phase AC 220V 43 3 Phase AC 380V Model HLP SV 0D75 23 A Serial No SV means SV series Trade Mark Inverter Capacity 0 D 75 means 0 75KW Software Version...

Page 7: ...l Install the inverter in a safe location avoiding high temperature direct sunlight humid air or water l Keep the inverter from the reach of children or persons not concerned l The inverter can only...

Page 8: ...n or even damage of the inverter 2 During the Power up Danger l Do not plug the connectors of the inverter during the power up to avoid any surge into the main control board due to plugging which migh...

Page 9: ...linkage of DC intermediate circuit l Be aware that there may be high voltage on the DC link even when the LEDs are turned off l Before touching any potentially live parts of the VLT Micro wait at lea...

Page 10: ...0Hz 3 7 3 7 30002301 HLPSV00D423A 3 200 240V 50 60Hz 0 4 1 0 2 5 0 4 30002302 HLPSV0D7523A 3 200 240V 50 60Hz 0 75 2 0 4 2 0 75 30002303 HLPSV01D523A 3 200 240V 50 60Hz 1 5 2 8 6 8 1 5 HLPSV02D223A 3...

Reviews: