HMPRO36AD OPERATOR’S MANUAL
www.holemaker.com
13
PRO 36 AD
3.5. Replacing the motor brushes
Check
the
condition
of
the
carbon
brushes
every
100
work
hours.
To
do
this,
unplug the
machine from the power source, and unscrew the cover (
1
, Fig. 6). Next, unscrew the
pressing plate (
2
), and then remove the brush holder (
3
) and the brush (
4
). If the
length of the brush is less than 5 mm (3/16’’), replace both brushes with new ones.
To install brushes, proceed in reverse order. After the replacement, run the motor
without load for 20 minutes.
Fig. 6.
Replacing the brushes
This document is protected by copyrights.
Copying, using, or distributing without permission of PROMOTECH is prohibited.
14
1
2
3
4