5
● When the meter is powered on, the meter is in the auto range mode;
press this button to select a specific measurement range.
● Press this push button more than 2 seconds the meter returns to auto
range.
3
.MAX/MIN
● Pressing this button the meter enters the dynamic record mode.
● In the dynamic record mode, pressing this button again cycles
MAX,
MIN , AVG , MAX-MIN
and
Present Reading
on.
4
. HOLD
● Pressing this button, the meter enters the auto data hold mode and
“H” is displayed on the LCD.
● The data hold function allows the operator to hold a displayed value
on the LCD while the analog bar graph continues to display the updated
value.
● In the auto hold mode the meter can display a new value when a new
and stable value is on the input and the Beeper will sound.
● Pressing this button for more than 1 seconds, the meter exits the
HOLD mode and returns to the normal state.
● Pressing the button for more than 2 seconds turns the backlight
on,look the Selector Knob more clearly, pressing it again turns it off..
5
.REL
△
● Pressing this button, the meter enters relative measuring mode,
“
REL▲
”
is displayed on the LCD and the present reading becomes the