2
and continuity test on a live power system.
Do not apply voltage between the test terminals and test terminal
to ground that exceed the maximum limit record in this manual.
Exercise extreme caution when measuring live system with
voltage greater than 60V DC or 30V AC.
Change the battery when the “ ” symbol appears to avoid
incorrect data.
Use the DMM indoor, altitude up to 2000m and temperature 5°C
to 40°C.
Maximum relative humidity 80% for temperatures up to 31°C,
decreasing linearly to 50% relative humidity at 40°C.
1.9 In locations subject to radio frequency interference, the
product may malfunction and it resets automatically when leaving
this environment.
Meter Description
■
Terminals
Refer to table 1 for terminal function
Terminal
Function
COM
Common terminal for all measurement
V/
Ω/
HzT
Volts , Ohm , Diode , Freq. , Temp. and Cap. Measurement and
square wave output terminal
Clamp
μ
AmA
Clamp
,
Microampere, milliampere current measurement terminal
20A
Ampere current measurement terminal
Table 1. Terminals