background image

760J

3 1/2 DIGITAL AUTOMATIVE ENGING

ANALYZER MULTIMETER OPERATION

MANUAL

This instrument is a compact , rugged , battery operative,

handhold 3 1/2 digits automotive engine analyzer multimeter for
measuring RPM,DWELL ANGLE, DCV, ACV, OHMS, DIODE,
CONTINUITY, DCA TEMPERATURE .It is an ideal instrument for
all drivers.

1. Panel Layout

1

LCD Display

2

POWER Switch

Boot Up / Shutdown

3

Function switch indicator lamp key: Pressing the button turns

the f unction switch indicator lamp on

pressing it again turns it off.

4

Data-hold Switch (HOLD)

Pressing this button, the meter enters the

auto data hold mode and “HOLD” is displayed on the LCD.
5

Back Light Button Switch: Pressing the button turns the

backlight on

pressing it again turns it off.

6

Function switch indicator lamp

7

hFE Input Jack

8

Rotary Switch: use this switch to select functions and ranges

9) mechanical blocking

system.

10

V Ω/T+ Input Jack

20A Input Jack

T- Input Jack

COM

Input Jack

2. SPECIFICATIONS
2.1 GENERAL SPECIFICATIONS

Display : 3 1/2 digits LCD with a max . reading of 1999
Polarity : Automatic negative polarity indication..
Zero adjustment : Automatic.
Overrange indication : only the “1” display.
Lowbattery : The “

” is display .

Safety standards :

CE EMC/LVD

.

The meter is up to the

standards of

IEC1010 Pollution Degree 2, Overvoltage

Category

or double insulation

.

Operating environment : Temperature 32 to 104

(0

to 40

),

humidity<85% RH.
Storage environment :

Temperature –4 to 140

(-20

to

60

),humidity<95% RH.

Power : Single, standard 9-volt battery, NEDA 1604IEC 6F 22.
Dimension : 190mm×88.5mm×27.5mm
Weight :Approx. 320g(including battery and holster).

2.2ELECTRICAL SPECIFICATIONS

Accuracy is ±(% of reading

number in last digit) at

23±5

, <75% RH.

2.2.1 DC Voltage

Range

Accuracy

Resolution

200mV

±(0.5% of rdg + 8digits)

100μV

2V

1mV

20V

10mV

200V

100mV

1000V

±(1.5% of rdg + 8 digits)

1V

Impedance : 10MΩ
Overload protection: 1000V DC/AC RMS.

2.2.2 AC Voltage

Range

Accuracy

Resolution

200mV

±(2.0% of rdg + 10 digits)

100μV

2V

±(1.5% of rdg + 10 digits)

1mV

20V

10mV

200V

100mV

750V

±(2.5% of rdg + 10 digits)

1V

Impedance: 10MΩ
Frequency response:
200V: 40Hz------400Hz
750V: 40Hz------200Hz
Overload protection: 500V DC/AC RMS.

2.2.3 Resistance:

Range

Accuracy

Resolutio

n

200Ω

±(1.2% of rdg +15 digits)

100mΩ

20kΩ

±(0.8% of rdg +8 digits)

10Ω

200kΩ

100Ω

20MΩ

±(2.5% of rdg + 15 digits)

10kΩ

200MΩ

±

5.0% of

rdg-10

+30 digits

1 kΩ

Overload protection:

250VDC/AC RMS.

2.2.4 DC Current

Range

Accuracy

Resolutio

n

20A

±(2.0% of rdg + 10 digits)

10mA

Overload protection:20A/250V fuse 20A up to 10 seconds

1.2.5 Temperature (Using K type thermocouples probe)

Scale

Accuracy

Resolution

(-20

1000)

±(3%of rdg +2 digits)

400

1

±(3.5%of rdg +5 digits)≥400

(-4

1800)

±(3%of rdg+2 digits)

750

±(3.5%of rdg +5 digits)≥750

2.2.6

Diode test:

Range

Description

Test condition

Display

read

approx.

Forward voltage of

diode.

Test current : 1±0.6mA
Test voltage : Approx. 1.5V

Overload protection: 250V

DC/AC RMS

2.2.7

Continuity Test

Range

Description

Test condition

Audible indication: Less

than 80Ω Approx

Overload

protection:

250V DC/AC RMS

2.2.8 Tachometer

500-10000RPM:

±(1.5%of rdg

8 digits)

Overload protection:

250V DC/AC RMS

2.2.9

Dwell

:

±(1.5%of rdg

8 digits)

3 CYL

0 - 120.0°

4 CYL

0 - 90.0°

5CYL

0 - 72.0°

6CYL

0 - 60.0°

8CYL

0 - 45.0°

2.2.10 Transistor hFE Test

(1) Set the FUNCTION switch the “hFE” range.
(2) Determine whether the transistor is NPN or PNP and locate
the Emitter. Base and collector leads. Insert the leads into the
proper holes in the socket on the front panel.
(3)

The display will read the approximated hFE value at the

test condition Base current 10uA, Vce 3V.

2.2.11

back light

Press button "LIGHT" backlight illume, Again press once
backlight breath go out.
2.2.12 Function switch indicator lamp:

New style patent of