Operating Instructions
145 052
111
C 9700 ... C 9.88 H
Operating the Implements
Operating Variable Pump* for Implements (setting
from 0 to 100 litres)
The variable pump for the implements is a device for driving
attachments with a high hydraulic power demand such as a
spiral-bladed lawn mower. It draws its oil from the working
hydraulics tank with a filling quantity of approx. 45 litres and
is controlled from the driver's station.
-
Connect the hydraulic hoses of the implements to the
screw couplings (1) and (2) and the leakage oil cou-
pling (3).
-
Set the switch for the driving program (4) to one of the
required driving programs.
NOTE
The variable pump can not be turned on
without a driving program being selected.
ATTENTION
Turn on the starting safety switch (7) only at
low engine speed.
* Option
Bild_092
1
2
3
Bild_091
4
-
Set the rotary knob (5) to 0.
-
Release the lock at the starting safety switch (7) and
depress the switch. The indicator in the switch comes on.