Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
2. Pulse Mode
OR
2. Toggle Mode
3 (1-99) # (factory default)
The relay time is 1-99 seconds. (1 is
50mS.)
(Default is 5 seconds)
3 0 #
Sets the relay to ON/OFF Toggle mode
3. Exit
*
Set Access Mode
For Multi cards/ PINs access mode, the interval time of reading cards/inputting PINs can not
exceed 5 seconds, or else, the H-TAG will exit to standby automatically.
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
2. Card access
OR
2. Card + PIN access
OR
2. Card or PIN access
OR
2. Multi cards /PINs access
4 0 #
4 1 #
4 2 #
4 3 (2~9) #
(Only after reading 2~9 cards or inputting
2~9 PINs, the door can be opened)
3. Exit
*
Door Detecting
Door Open Too Long (DOTL) warning
. When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the
inside buzzer will beep automatically to remind people to close the door and continue for 1 minute
before switching off automatically.
Door Forced Open warning.
When used with an optional magnetic contact or built-in magnetic
contact of the lock, if the door is opened by force, or if the door is opened after 60 seconds of the
electro-mechanical lock not closed properly, the inside buzzer and alarm output will both operate.
Enter Master code # or valid user card /PIN to silence
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
2. To disable door open detection
OR
2. To enable door open detection
5 0 # (factory default)
5 1 #
3. Exit
*