background image

Battery Saver/Sleep Mode 

The ergoFET’s self activating 'sleep' mode is designed to extend battery life. The ergoFET goes to sleep 

when the unit has not received any input for three minutes. The unit can be 'awakened' from sleep mode by: 
Pressing the Reset button, or Turning the unit off for five minutes or more. 

NOTE:  When using ergoFET RF with Bluetooth / FET Stick and software: if the ergoFET has not received any 
input for three minutes or crossed the threshold setting, “sleep” mode will activate and signal transmission will 
stop.  Simply press the reset button and the signal will start transmitting again.   

The ergoFET

 

batteries are designed to provide constant power throughout the battery life. As result, 

performance declines rapidly in the last few percent of battery life. To avoid any interruption of testing 
capability, due to low battery power, Hoggan Scientific recommends you change batteries when the power 
check reading reaches approximately 15%. 

ergoFET Testing 

   The ergoFET was developed to eliminate the subjective nature of testing by giving clear, accurate, objective, 
quantified force measurements. ergoFET increases testing reliability and accuracy. 

    For best results, be sure to install the proper attachment for the area being tested, and check to ensure that 
attachments are securely affixed to the unit, and that the unit is properly positioned for maximum surface area 
contact and direct force application. 

    The ergoFET is ambidextrous. It can be held in either the left or right hand for compression testing, or you 
may switch hands from test to test, depending on stabilization requirements.  To secure the ergoFET in your 
hand, place the strap over your hand, and perform one hand direct push test.  See Image H below. 

Image H 

Page 10 

Summary of Contents for ergoFET

Page 1: ...Dual Function Push Pull Force Gauge ergoFET User Guide...

Page 2: ...flexible mix and match devices for measuring force angle velocity torque and vibration in any combination for real time job analysis and ergonomics research The only limitation to what the ergoPAK can...

Page 3: ...ff Switch 6 Sleep Mode 6 Reset Button 6 Threshold Button 7 LCD Windows 7 Display Settings 8 Force Measurement 8 Bluetooth FET Stick 9 Battery Check 9 Battery Saver Sleep mode 10 ergoFET Testing 10 11...

Page 4: ...es in force Information from the gauge is displayed in two LCD windows Peak Force and Duration Sec The Peak Force LCD shows the force being applied against the transducer pad during the compression te...

Page 5: ...en software ordered Specifications Weight l lb Power Source 3 7V LI ION lithium batteries Controls On Off Reset Threshold Operating Temperature 52 92 11 33 C Humidity 80 60 non condensing Capacity 300...

Page 6: ...rt the ergoFET in the hard sided protective carrying case provided Operating Features On Off Switch The On Off switch slides left and right to turn the unit on and off Even though the ergoFET is equip...

Page 7: ...shold setting is designed for more sensitive lower force readings such as when testing finger and hand muscle weakness Greater care must be used when positioning the unit while in the Low setting as t...

Page 8: ...ton for five seconds the display will go blank only showing hash mark for the unit of measurement currently chosen Press the Threshold button to toggle through options Press the Reset button to return...

Page 9: ...atteries will need replacement ergoFET is equipped with power check feature to allow you to see remaining battery power To conduct power check follow these four steps 1 Put the unit into data retrieva...

Page 10: ...ife To avoid any interruption of testing capability due to low battery power Hoggan Scientific recommends you change batteries when the power check reading reaches approximately 15 ergoFET Testing The...

Page 11: ...in situations To insert handle push aside strap on underside of gauge The screw insert is located on the underside of the gauge Thread the screw portion of handle into the insert and tighten until snu...

Page 12: ...ll display new peak force the number representing the 2nd most recent test and test duration for the test displayed Each time you press the Threshold button the unit will move backward to the previous...

Page 13: ...n unit Carefully remove the batteries from their holders When installing new batteries make sure the positive posts align with the marks on the ergoFET body If segments do not light up after installin...

Page 14: ...and may increase the possibility of injury to the user or cause additional damage to the unit When ordering Replacement Parts please take the unit out of service and complete the following 1 Identify...

Page 15: ...Hoggan Scientific LLC 3653 West 1987 South Bldg 7 Salt Lake City UT 84104 Ph 800 678 7888 801 572 6500 Fax 800 915 3439 E mail contact hogganhealth net www hogganhealth net...

Reviews: