ELECTRICAL SPECIFICATIONS
MINIMAL BRIGHT LEVEL SETTING
PARAMETER
VALUE
Supply voltage & Frequency
220-240V ~ 50Hz
Dimming technology
Auto Detect Trailing/Leading edge driven control. Minimal bright
level setting can be set by user manually.
Rating
10-100W: incandescent lamps, high voltage
halogen lamps and electronic step-down converter
for extra low-voltage incandescent lamps.
3-250W: dimmable LED lamps.
Compatible loads
Dimmable LED lighting
with compatible Electronic
Transformers
Incandescent lighting,
MV Halogen lamps
LV Halogen Lighting
with electronic transformers
LV Halogen Lighting
with iron core transformers
Operating Temperature
0°C - 35°C
Operating Humidity
10 - 90% R.H.
Mounting Centres
82mm EU Pattern Plate
NOTE:
Operation at elevated temperatures or voltages may cause the thermal protection
circuit to operate. If this happen, decrease the connected load to prevent re-occurance.
HOW TO SET THE MINIMUM BRIGHT LEVEL:
Adjust the required minimum brightness then short
press 5x within 5 seconds to save a minimum level,
your LED lighting will flash 3 times.
HOW TO RESET THE MINIMUM BRIGHT LEVEL:
Short press 7x within 5 seconds to reset the
minimum level, your LED lighting will flash 3 times.
Adjust to required minimum brightness and short
press 5x within 5 seconds to save minimum level,
your LED lighting will flash 3 times.
Each step must be performed within 15 seconds, if not, it will time out and go to the auto exit program without saving.
EN