Seite 38 von 99
Recommended service steps
In case of an error it is recommended to perform some service code to check the system. The
following are some common service codes for this job.
•
C28
- Indicate the content of the error record
•
C74
- Check the incremental encoder of the main shaft
•
C54
- Some more testing for the incremental encoder of the main shaft
•
C98
- Check the incremental encoder of the power clamp
•
C63
- Continuous measurements for test of valid results
•
C56
- Check the pedal switches. The switches and the Function-Code to lock the power clamp
should be checked if the power clamp does not work.
•
C75
- Check Voltages of SAPE potentiometers (AD8, AD9, AD10) or
perform STEP 1 of C80 and C82
•
C80
- Check Voltages for left SAPE
ATTENTION This is a calibration function; interrupt this function after the test in STEP 1 with
the STOP or ESC key
•
C82
- Check Voltages for right SAPE
ATTENTION This is a calibration function; interrupt this function after the test in STEP 1 with
the STOP or ESC key
•
C55
- Check lines Voltage
•
C110
- Check VCC Voltage
•
C111
- Check belt tension
The following codes allow some deeper tests of the vibratory system:
•
C67
- Indicate the phase stability/shift of the vibratory system
•
C72
- Measure the angular deviation of the vibratory system
•
C63
- Continuous measurements to check measurement deviation.
Summary of Contents for Snap-on Y2k
Page 1: ...SERVICE of the Y2k balancing platform Seite 1 von 99 ...
Page 2: ...The vibratory assemblies of the Y2k balancing platform L R L R S S M Seite 2 von 99 ...
Page 32: ......
Page 35: ...Seite 35 von 99 ...
Page 66: ...Seite 66 von 99 Figure 1 JBEG B9000 B9450 User Interface ...
Page 67: ...Seite 67 von 99 Figure 2 JBEG B9460 User Interface ...