the weight will remain on the display for 120 seconds after the item has
been removed from the scale so the weight can easily be read without
any interference.
1.
Place the item on the scale platform.
2.
Press the
HOLD
key. The “.” indicator will turn-on.
3.
Remove the item from the scale platform. The item’s weight reading
will remain on the display.
Press the
TARA
key to cancel the hold reading and return the scale to
reading zero. You may also press
HOLD
key to exit Hold function.
CALIBRATION
When to calibrate
Calibration may be required when it is initially installed, if the scale is
moved to a substantial distance.
This is necessary because the weight of a mass in one location is not
necessarily the same in another location. Also, with time and use,
mechanical deviations may occur.
How to calibrate
1.
Before entering calibration mode, press
[I/O]
to turn the power on
for 1 minutes.
2.
Press
[CAL]
key for 2 seconds, the display will show “CAL”, and
then show flashing “0”.
3.
Press
[CAL]
key, the display will show “0”, then the display will
return to the random flashing calibration weight after 1 seconds.
4.
Place the calibration weight on the platform.
Press
[CAL]
key, the display will show "PASS", then it will return to
normal weighing. Now calibration is complete.