Clock:
Real time clock with AM/PM or 24H mode. Battery
backed up.
Additional
relay functions:
S1 can be set up as a timer with real time
ON/OFF timing.
S3 and S4 can operate in proportional mode.
S3 and S4 can also be lprogrammed to track
temperature for temperature control or alarm.
S2 configurable as a high/low alarm.
Pulse output:
P1 and P2 are
(contact closure)
non-polarised pulsed
outputs. Minimum pulse duration 250mS. 500 volt
isolation to instrument output. Maximum voltage
across terminals 100 volts.
Pulse rate:
Select maximum pulse rate per minute from 50 to 100
pulses. Slope of pulse frequency 0.5pH to 2pH
above/below SET POINT.
Power supply:
240V/50H 8VA max.
Construction:
Fully sealed construction with hinged clear acrylic
front cover. IP55 specifications.
Dimensions:
(W)215mm x (H)185mm x (D)115mm.
PAGE 4