Hoffrichter AquaTREND III-H5 User Manual Download Page 4

Safety Instructions

4

humidifier   

AquaTREND III-H5

Before first use of your 

AquaTREND III-H5

, please

read this manual thoroughly!

Keep the manual in a safe place, so that you will be able
to consult it whenever necessary.

Please comply with the following information in
order to prevent possible dangers:

1. Use the device exclusively in combination with 

TREND

therapy device and comply with the user 

information for this devices. 

2. Use only those accessoires recommended and 

offered by manufacturer or your dealer.

3. Do not use 

AquaTREND III-H5

if it is damaged or 

is not operating correctly and report such 
circumstances to your dealer immediately.

4. Place the device on a flat and stable base avoiding 

tilted positions.
N

Ne

ev

ve

err  ttrra

an

ns

sp

po

orrtt  o

orr  ttiilltt  tth

he

e  tth

he

erra

ap

py

y  d

de

ev

viic

ce

e  w

wiitth

h  tth

he

e  

h

hu

um

miid

diiffiie

err  ffiitttte

ed

d  a

an

nd

d  ffiilllle

ed

d,,  o

otth

he

errw

wiis

se

e  w

wa

atte

err  c

co

ou

ulld

d  

e

en

ntte

err  tth

he

e  tth

he

erra

ap

py

y  d

de

ev

viic

ce

e  a

an

nd

d  d

da

am

ma

ag

ge

e  iitt..

5. Never place the therapy device with humidifier fitted 

and filled in the sun or close to heaters etc.

Attention!

H

O

FFRICHTER

GmbH shall not be held liable for any

damages or consequential damages, consequences
for safety, reliability and performance of the device, in
case of:

Tampering, modifying, adding expansion features, 

adjustment, repair and maintenance executed by 
persons who have not been authorized by us.

Building in accessory and spare parts which have 

been fabricated by other manufactures and not 
been released by us for use in the humidifier  

AquaTREND III-H5

.

Using the device in a different way than what has 

been described in the manual.

The hygiene- and cleaning specifications in this 

manual aren´t observed.

BedienAquaTRENDIII-H5.qxd  28.03.2006  09:33  Seite 4

Summary of Contents for AquaTREND III-H5

Page 1: ...USER S MANUAL plug in humidifier for TREND devices AquaTREND III H5 BedienAquaTRENDIII H5 qxd 28 03 2006 09 33 Seite 1 ...

Page 2: ...ack The serial number is on the type identification plate to be found on the reverse of the device In case of any query or complaint please always state the serial number Conformity The device complies with the requirements of the directives 93 42 EWG 2 humidifier AquaTREND III H5 0123 BedienAquaTRENDIII H5 qxd 28 03 2006 09 33 Seite 2 ...

Page 3: ...nical description of AquaTREND III H5 06 Device Description 07 Operating AquaTREND III H5 08 Cleaning 09 Problems 10 Technical Data 11 Sales and Service 12 Contents 3 humidifier AquaTREND III H5 BedienAquaTRENDIII H5 qxd 28 03 2006 09 33 Seite 3 ...

Page 4: ...e e w wiit th h t th he e h hu um miid diif fiie er r f fiit tt te ed d a an nd d f fiilllle ed d o ot th he er rw wiis se e w wa at te er r c co ou ulld d e en nt te er r t th he e t th he er ra ap py y d de ev viic ce e a an nd d d da am ma ag ge e iit t 5 Never place the therapy device with humidifier fitted and filled in the sun or close to heaters etc Attention HOFFRICHTER GmbH shall not be h...

Page 5: ...s for treatment of obstructive sleep apnea OSA in adult patients weighing at least 30 kg The AquaTREND III H5 humidifier accessory is not intended for use with medications aromatic oils or other substances added to the humidifier water Refer to your TREND manual for more information Intended Use 5 humidifier AquaTREND III H5 BedienAquaTRENDIII H5 qxd 28 03 2006 09 33 Seite 5 ...

Page 6: ...ent the mucous membranes in the upper respiratory passages from drying out The level of heating can be adjusted in stages from 0 to 5 and can thus be adapted to the individual needs of the patient AquaTREND III H5 has an integral storage This ensu res that the last heating set is stored when the therapy unit is switched off or the humidifier is removed AquaTREND III H5 can only be used on TREND th...

Page 7: ...END III H5 Air outlet connection for therapy tube Cap Reservoir with heating surface Max amount of filling Touch pad for heating stages LED for heating stage 0 5 Air inlet Contact pins Seal BedienAquaTRENDIII H5 qxd 28 03 2006 09 33 Seite 7 ...

Page 8: ...humidifier over to your TREND device and fit it In so doing ensure the following nPress the release button on top of the therapy device nFeed the contact pins and air inlet to the therapy device without turning or tilting the humidifier n The rear panel of the humidifier must come flush with the TREND without any gap n The release button must be heard to engage On AquaTREND III H5 the heating leve...

Page 9: ...onal Open the humidifier by turning the cap anticlockwise and the reservoir in opposite directions Empty the reservoir and clean it under running water Remove the lime scale residue from it by wiping it with a soft cloth If it is ever necessary to remove stubborn scale residu es we recommend the use of a normal domestic scale remover or by filling the heating dish with a weak vine gar solution and...

Page 10: ...hed on Water in the therapy tube The heating is set to high select a lower heating stage No or inadequate humidification Set a higher heating stage Pain in nose nasal cavity or ears Possible inflammation Stop therapy and contact your doctor Dryness and irritation of nose Humidification level is inadequate Set higher heating level discuss with your and throat doctor Head cold wet nose sinus Head co...

Page 11: ... approx 290 g Operating voltage 15 22 V DC Power Consumption 0 20 W Heating steps 1 5 Max filling quantity approx 200 ml Product MPG class IIa Classification according to DIN EN 60601 1 protective class II Type BF equipment Data subject to technical alteration BedienAquaTRENDIII H5 qxd 28 03 2006 09 33 Seite 11 ...

Page 12: ...941 AquaTREND III H5 humidfier Typ 5CP961 AQT III H5 eng 0306 02 HOFFRICHTER GmbH Mettenheimer Straße 12 14 19061 Schwerin Germany Tel 49 385 39925 0 Fax 49 385 39925 25 Mail info hoffrichter de URL www hoffrichter de MANUFACTURER SALES SERVICE BedienAquaTRENDIII H5 qxd 28 03 2006 09 33 Seite 12 ...