background image

www.procontechnology.com.au

 

 

Phone: (03) 98306288 

1 ~ 15V

 

1 ~ 30V

 

60A

 

30A

 

60A

 

30A

 

5A

 

3A

 

40mVp-p

 

0.1% + 5mV

 

0.05% + 3mV

 

200~240VAC / 50Hz ( or on request )

 

>85%

 

>0.97 at optimal load

 

3 digit LED display

 

+/-1% + 1 count

 

Green LED for power on/off indication 

 

Red LED for overload/short circuit indication

 

Remote Control & Remote Sensing

 

Variable Speed thermal static control fan

 

0 ~ 40 Degree C

 

Overload (Constant Current Limiting), Short Circuit,  

OTP (Over Temperature Protection) & OVP (Over Voltage Protection)

 

CE-EMC: EN 55022   CE-LVD:EN 60950

 

220x110x360mm

 

4.9Kg

 

 

 

 

4.5 REMOTE ON/OFF 

The remote on/off can be activated in any mode – Normal or Remote. By default, pins 7 and 8 are open 
and the output is on. Shorting pins 7 and 8 turns the output off. 

 
 

5.  SPECIFICATIONS 

 

Variable Output Voltage 

Total Rated Output Current 

(Main + Auxiliary Output) 

Rated Output Current (Main) 

 

Rated Output Current (Auxiliary) 

Ripple and Noise 

Load Regulation 

Line Regulation 

Input Voltage 

Efficiency 

Dynamic Power Factor Correction 

Voltmeter and Ammeter Display 

Meter Accuracy 

Indicator 

 

SPS-9600 

 

 

 SPS-9602

 

 

Special Feature  

Cooling Method 

Operating Temperature 

Protection 

 

 

Approvals 

 

Dimensions (WxHxD) 

 

Weight 

 

Remote Socket Pin Assignment 

PIN 

FUNCTIONS 

REMARKS 

Internal DC +5V 

Maximum 50mA 

Voltage Adjust (V) 

0 ~ 5V 

Ground 

 

N.A. 

 

N.A. 

 

N.A. 

 

Output OFF (-) 

Open-circuit 5VDC 

Output OFF (+) 

Short-circuit 1.6mA 