Introduction 5
HRT1
HP-313
SYSTEM CERTIFIED MOUNTING OPTIONS FOR ENCLOSURE STYLE 3 AND 7:
(MX_) METER
MOUNTED
NOTE: USED WITH “X” RISER, AND 1" X ¾" SS ADAPTER. PROCESS
TEMP -40°C TO +70°C.
(MA_) METER MOUNTED
NOTE: USE WITH A (X-ATEX) RISER. PROCESS TEMP -40°C
TO
+70°C.
(RX_)
REMOTE MOUNTED
NOTE: USE WITH “X” RISER. INCLUDES “E2” JUNCTION BOX AND
1" X 3/4" SS ADAPTER.
(RA_)
REMOTE MOUNTED
NOTE:
USE WITH A (X-ATEX) RISER. INCLUDES “E2” JUNCTION BOX.
UNION OPTIONS:
(___U1) OPTIONAL 1" MALE X 1" FEMALE EX-PROOF UNION
NOTE: USE WITH MX AND RX OPTIONS
(___U2) OPTIONAL 3/4" MALE X 3/4" FEMALE EX-PROOF UNION
NOTE: USE WITH MA AND RA OPTIONS
EXPLOSION-PROOF ENCLOSURE RATINGS:
Canada/US Zones
Ex db IIB+H
2
T6; Gb; Ex tb IIIC T72°C Db; IP66;
Class I, Zone 1, AEx db IIB+H
2
T6; Gb; Zone 21, AEx tb IIIC T72°C Db; IP66:
ATEX/IECEX
:
II 2 G Ex db IIB+H2 T6 Gb
II 2 D Ex tb IIIC T72°C Db IP66
T1-T6 = -40°C to +70°C
SPECIAL FEATURES
MODEL
HRT1-( )-(
)-(
)-(
)-(
)-(
)-(
G
)
OPTION
( G )
(CE) CE MARK REQUIRED FOR EUROPE
(SP)
ANY SPECIAL FEATURES THAT ARE NOT COVERED IN THE
MODEL NUMBER, USE A WRITTEN DESCRIPTION OF THE -SP.
(X)
NO SPECIAL FEATURES.
Summary of Contents for HRT1
Page 2: ......
Page 3: ......
Page 4: ......
Page 14: ...Introduction 6 HP 313 HRT1 This Page Intentionally Left Blank...
Page 34: ...Operation and Maintenance 26 HP 313 HRT1 This Page Intentionally Left Blank...
Page 48: ...HART Communications 40 HP 313 HRT1 This Page Intentionally Left Blank...
Page 53: ...Appendix B Declaration of Conformity 45 HRT1 HP 313 APPENDIX B Declaration of Conformity...