Appendix B
- Communications
34
HP-306
Command
Description/Allowed Data/Response
AF
Out High
Minimum is the Out Low Setting (LF) to a maximum of the
following:
“99999.999”
if RD = 3
“999999.99”
if RD = 2
“9999999.9”
if RD = 1
“ 99999999”
if RD = 0
“20mA FLOW =(DATA)”
PS
Pulse Scale
“0”
for OFF
“1”
for 1
“10”
for 10
“100”
for 100
“PULS SCALE=(DATA)”
(DATA)
shall be:
“OFF”
for OFF
“1”
for 1
“10”
for 10
“100”
for 100
FO
Pulse Frequency
“1”
“2”
“4”
“8”
“PULS FREQ =(DATA)”
PA
Password
“0”
to
“9999”
“PASS WORD =(DATA)”
LK
Lock Unit
“0”
for NO
“1”
for YES
“LOCK UNIT =(DATA)”
(DATA)
shall be:
“YES”
for YES
“NO”
for NO