Specification
4
HP-306
Reset:
Signal Type:
Contact closure to DC common
High (Logic 1):
4 to 30 VDC
Low (Logic 0):
< 0.5 VDC
Min Current:
0.5 mA
Min On:
25 msec
Internal Pull-up:
100 k
Ω
to +3.3 VDC
External Magnet:
Activates internal reed switch
2-3
Battery Powered Version
Type:
Two C-size lithium battery packs.
Battery Life:
6 years typical
*
10 years typical
*
for external power.
*
With the pulse output OFF. With pulse output ON 30% less.
2-4
DC Power/Loop Powered
Voltage:
8 to 30 VDC
Current:
< 4 mA
Loop Burden:
8 VDC maximum
Supply Backup:
One (1) C-size Lithium battery
Protection:
Reverse polarity protected
2-5
AC Power
Voltage:
100 to 240 VAC
Frequency:
47 – 440 Hz
Current:
150 mA
Line Regulation:
0.3%, typ
Protection:
Short circuit, Over voltage, & Over
temperature
Supply Backup:
One (1) C-size Lithium battery
2-6
Analog (4-20mA) Output Option
Scale:
4 – 20 mA follows rate.
Accuracy:
0.02% of Full Scale @ 20ºC.
Temperature drift:
40 ppm/°C
Update Time:
2.0 seconds.
Connection:
Two wire.
Protection:
Reverse polarity protected
Summary of Contents for HIT-2A
Page 2: ......
Page 6: ...HP 306...
Page 10: ...Introduction 2B HP 306 This page intentionally left blank...
Page 14: ...Specification 6 HP 306 This page intentionally left blank...
Page 18: ...Theory of Operation 10 HP 306 This page intentionally left blank...
Page 20: ...Installation 12 HP 306 TTL Redi Pulse Pick up with DC Power Reset Input Heater Option...
Page 26: ...Installation 18 HP 306 This page intentionally left blank...
Page 34: ...Operation and Maintenance 26 HP 306 This page intentionally left blank...