Hoeptner Freeze Flow Sanitary Yard Hydrant Installation Instructions Download Page 2

Hydrant is designed to use clean water at 20 psi to 100 psi. Should 

leakage occur at packing nut, simply tighten nut until leakage stops. If 

tightening nut does not stop leakage, remove nut and replace with 

packing.   Figure 5

1.)

OPERATION AND MAINTENANCE

Packing Nut Leak

Sanitary Yard Hydrant

Operation and Maintenance Instructions

Hoeptner Products

HOEPTNER PERFECTED PRODUCTS

7796 Oak Spring Circle, Gilroy, CA 95020 * Ph 408-847-7615 / Fax 408-847-0675

[email protected] * www.freezeflow.com

packing nut

Figure 5

Float Valve

Assembly

Unscrew handle and operating rod from hose bib.
Lift out operating rod and change o-ring seal on tip.
Replace operating rod and tighten packing nut.

2.)

No adjustment is necessary.

5.)

To prevent unauthorized use,  the hydrant wheel handle can be removed.

6.)

NOTE:  If the hydrant has not been used for a long period of time, it is advisable to flush the hydrant for

60 seconds when water is used for drinking.

4.) Handle/operating rod adjustment

To Change Seal, O-ring

Unscrew packing nut from under handle.

Leakage from float valve is typically due to not flushing supply lines properly.

3.)

Replace ball and o-ring after cleaning.
Reassemble Float Valve.

Remove ball and o-ring.

To clean, unscrew Hex Cap from round base.

Leakage from float valve