Ordering information

product 

quantity 

code number

MacroVue UV-25 Transilluminator  
21 × 26 cm viewing surface, 302 nm. 
    115 V 

UV25-115V 

    230 V 

UV25-230V

302 nm UV lamp, 8-W 

UVLM-8

254 nm UV lamp, 8-W 

UVLS-8

UV-transmitting work surface 

UVT-WS

Fuses for 115 V and 230 V models 

PSF1A-5B-5X20

Summary of Contents for MacroVue UV-25

Page 1: ...user manual MacroVue UV 25 um UV25 IM Rev B0 08 10 MacroVue UV 25 transilluminator...

Page 2: ...al and Electronic Equipment WEEE v UV transilluminator function 1 Unpacking 2 Specifications 2 Safety information 3 Operating instructions 4 Care and maintenance 5 Troubleshooting 8 Bibliography 9 Cus...

Page 3: ...mportants d utilization Pour une bonne compr hension et une utilisation en s curit maximale il convient de lire enti rement ce manuel Tous vos commentaires sur ce manuel seront les bienvenus et veuill...

Page 4: ...que sea la causa que se deban a la utilizaci n defectuosa e incorrecta del producto Wichtige benutzerinformationen F r ein vollst ndiges Verst ndnis und eine sichere Handhabung dieses Produktes ist e...

Page 5: ...nzia e responsabilit Hoefer Inc garantisce che prima della consegna il prodotto stato collaudato a fondo per soddisfare i requisiti specificati La garanzia inclusa nelle condizioni di consegna risulta...

Page 6: ...echar el equipo Dieses Symbol kennzeichnet elektrische und elektronische Ger te die nicht mit dem gew hnlichen unsortierten Hausm ll entsorgt werden d rfen sondern separat behandelt werden m ssen Bitt...

Page 7: ...illumination This visualization method is especially suitable for double stranded nucleic acids but is less sensitive for visualizing single stranded nucleic acids The MacroVue UV 25 filter surface is...

Page 8: ...Specifications Ultraviolet lamps UV 25 Six 8 W 302 nm UV dual bi pin discharge type tubes Filter The factory installed filter is for 254 nm and 302 nm lamps only Do not use with 365 nm lamps The expe...

Page 9: ...UV blocking safety cover before switching the UV lamps on Always wear protective clothing even with the cover closed to prevent accidental exposure to UV radiation If the cover has been removed you mu...

Page 10: ...ective cover 5 Set the variable intensity dial to the highest setting and switch the power to on After a momentary flickering the UV lamps should light and be visible beneath the protective cover The...

Page 11: ...ce after each use Use a mild detergent and water on a soft cloth or sponge to clean the unit exterior Never use abrasive cleaners solvents or chloroform on any part p5 Caution Always unplug unit from...

Page 12: ...ution Turn the unit off and disconnect the power cord from the mains power 2 Remove the filter cover by unscrewing the four retainer screws located on the sides of the cover 3 If present remove the ta...

Page 13: ...power cord before replacing fuses 2 Insert a small flat blade screwdriver into the slot on the fuse module and turn it turn counterclockwise The spring loaded module cap will loosen Pull the cap fuse...

Page 14: ...tlet Remove and inspect the fuses Check that the lamps are properly installed Lamps flicker excessively Check that the variable intensity dial is in the highest position Check for proper line voltage...

Page 15: ...bridization signals Molec Biol Report 11 107 115 Reed K C and D A Mann 1985 Rapid transfer of DNA from agarose gels to nylon membranes Nuc Acid Res 13 7207 7221 DNA nicking Vollrath D and R W Davis 19...

Page 16: ...limination of PCR contamination WIlson K H 1992 UV Absorption Complicates PCR Decontamination BioTechniques 13 208 210 Sarkar Gobinda and Sommer Steve S 1991 Parameters Affecting Susceptibility of PCR...

Page 17: ...bsite at www hoeferinc com for the distributor in your area Or contact us directly at Hoefer Inc 84 October Hill Road Holliston MA 01746 1 800 227 4750 USA 1 508 893 8999 INT Email support hoeferinc c...

Page 18: ...umber MacroVue UV 25 Transilluminator 21 26 cm viewing surface 302 nm 115 V 1 UV25 115V 230 V 1 UV25 230V 302 nm UV lamp 8 W 1 UVLM 8 254 nm UV lamp 8 W 1 UVLS 8 UV transmitting work surface 1 UVT WS...

Page 19: ...84 October Hill Road Holliston MA 01746 Toll Free 1 800 227 4750 Phone 1 508 893 8999 Fax 1 508 429 5732 E mail support hoeferinc com Web www hoeferinc com 2010 Hoefer Inc All rights reserved Printed...