EQC-Counting Scale
User Manual
WS
:
Press this key is to set the value of unit weight. We
suggest the unit weight should be heavier than the
division (or sensitivity) of the scale. For a counting
scale 6/15kg x 2/5g, the unit weight should not be
lighter than 2g.
Example:
With the known unit weight at 10g, please key in
10
;
then press [
WS
] once; then 10g will be indicated on
UNIT WEIGHT LCD.
ALARM
:
1. Quantity Alarm:
<1> Press [
ALARM
] key to select
-PCS-
(showed
on UNIT WEIGHT LCD.
<2> Key in
100
(showed on WEIGHT LCD; then
press [
ALARM
] key again to confirm the
setting.
!!
Notice
:
The setting values under
-Hi-
mode
and
-
Lo-
mode must be
0
.
When the total quantity of measured subjects is
≧
100,
the scale will sound
beep
continuously.
2. Hi/Lo Weight Limit:
Example: setup Hi/Lo weight range at 10kg
±
500g.
8