11
5.3 Programming the temperature
5.3.1 Choice of HEAT /COOL mode
When
“TEMP“
is fl ashing.
To set the temperature regulation, press
. (To set the timer control (alternative to temperature control), press
▼
until TIME fl ashes, then press
and continue with item 5.4 of these instructions)
Flashing ( ).
Confi rm with
to select HEAT ( ) operating mode (control of connected Heaters) or use
▲
and
▼
to select
COOL ( ) (control of connected Cooling devices).
5.3.2 Temperature regulation
When
“P01“
is fl ashing, press
to program position 1.
(
P01
to
P08
can be selected using
▲
and
▼
)
When
“CHA”
is fl ashing, the
▲
and
▼
buttons can be used to select ‘CHA’ (change) or ‘dEL’ (delete).
If
“CHA”
is selected, press
to confi rm, the hours
“00”
will fl ash”.
Use the
▲
and
▼
buttons to set the hours between 0 and 23.
Press the
button, the minutes digits
“00”
will fl ash.
Use the
▲
and
▼
buttons to set the minutes between 0 and 59.
Press the
button, the desired temperature value will fl ash -
“25.0”
.
Use the
▲
and
▼
buttons to set the desired temperature value between 0 and 60.
If
“P02”
fl ashes, you can program further time periods in the same manner.
If you do not wish to set further time periods, press and hold the
button for a few seconds.
Note: It is not possible to enter turn-off times. The start time of, for example, P02 is the end time of P01. If only P01
is set, the programmed levels are maintained over 24 hour. It is advisable to program at least two time periods to
differentiate day values and night values.
Attention: If two or more times for the start of temperature control are identical, the error E5 appears on the display.