Troubleshooting
There are 26 ways to improperly connect two packs to a charger! After the
START/STOP
button is
pressed, a special battery checking sequence automatically checks every wire before initiating a charge.
It is possible to get an unrelated safety code from a simple wiring issue.
Operating errors appear as messages in the display. To determine the problem, look up the description
below. Correct the error. If errors continue, contact Hobby King Customer Service.
Code/Message Problem
Neg. Term. < 0V
Check pack wiring
Supply < 10 Volts
Input supply voltage is too low
Supply > 32 Volts
Input supply voltage is too high
Supply Unstable
Check for a loose supply connection or thin wiring
Ch2 No Add Up
Check pack wiring or dirty connectors
Chg. Overvoltage
Cell is too high
C2 Pack Detected
A pack was detected on channel 2 after starting charge
Series Chargers
Check Pack wiring. Check for 2 chargers on a series pack.
Low Voltage Cell
A cell is too low
Cell < 0.1V
The cell voltage is too low on a cell
Reverse Polarity
Check pack wiring
Node 10 < 0V
Check pack wiring
Ch2 Bad S. Count
Channel 2 couldn’t identify the pack. Check for correct node setting.
System Softstart
Check the power supply is big enough. Loose input connections.
2 Pack Con. Err.
Check pack wiring
Ch1 No Add Up
Check pack wiring or dirty connectors
Unbalanced Only
Unbalanced charge detected voltage on the node connector.
Ch1 has no pack
Check pack wiring or dirty connectors
Positive < 0V
Check bananas
Butt Not Pressed
The confirm chemistry mode button was not pressed
Pack Detect CH1
Unbalanced charge detected voltage on the node connector
Pack Detect CH2
Unbalanced charge detected voltage on the node connector
Charge Timeout
The pack is taking too long to charge
Bad Amps Setting
Charger safety check
Amps Not Raising
Check the banana wiring
Bad Fuel Table #
Corrupted preset. Factory restore the charger
Bad Lith Fuel Tb
Corrupted preset. Factory restore the charger
A123 < 2.7V/CELL
Cell low voltage
A123 > 3.8V/CELL
Cell high voltage
Options Corrupt
Factory restore the charger
L.Supply V.Limit
The supply voltage reached the cutoff
No Auto Amps
Auto amps are not allowed in some chemistries
Chem Not Found
Corrupted preset. Factory restore the charger
LIPO < 3.0V/CELL
Cell low voltage
LIPO > 4.2V/CELL
Cell high voltage
Set Amps >= 2A
Lower the amps setting
Bad Banana Tot V
Check the connectors. Clean the connectors.
Preset is Blank
Change presets or factory restore
No Fuel Table
Corrupted preset. Factory restore the charger
January 17, 2012 ver 1.0 www.revolectrix.com