background image

on model 256652/IDT)
Verification of shield integrity 
Cross talk detection in excess of 3dB + 0.3dB at 3.5Mhz 

between any two pairs 
Specially designed remote unit that enables one person to 
test installed cables 
Easy to read fault display and high speed testing 
Debug mode for detailed fault identification results 
Auto sleep mode and power off switch to decrease power 
consumption 

LANtest Pro Specifications

    

Connectors

LANtest Pro Main Unit 

RJ45 jack

Remote Unit 

RJ45 jack

    

Pairs tested

    1/2, 3/6, 4/5, 7/8 and shield

LED display

      

Horizontal: 5 Green LEDs

  for pair and shield display

                           

(1-2, 3-6, 4-5, 7-8 and shield)

      

TONE G. LED

 (for models 256652/LBT, 256652/TK,    
 256652/TFK and 256652/IDT)

      

Vertical: 5 Red LEDs 

for fault display and #ID display 

                    

(OPEN, SHORT, REVERSED, MISWIRE, 

      

SPLIT PAIRS and LOW BATTERY)

    For 256652/IDT the fault display shares with the #ID 
    Display (#1, #2, #3, #4) 

    Cable test length limit

    Minimum: 0.4m   Maximum: Over 200m 
    

Power:

    LANtest Pro:  6V alkaline DC battery 
    Remote identifier: No battery required

Dimensions:

    LANtest Pro: 125 x 52 x 30 mm (L x W x H) 
    

Low battery indicator 

LANtest Pro Cable Test Operation:

    1.Select "Cable" position on the toggle switch.
    2.Plug one end of the subject cable into the RJ45 jack on 

the master unit and the other end into the RJ45 jack on 
the remote terminator.

       

Note:

 

The remote terminator can be slipped and locked into the 

master unit for convenient testing of patch cables.

    3.Push the test button and check the results: First, check 

the 5 horizontally aligned green LED indicators (1-2, 3-
6, 4-5, 7-8, SHIELD) for integrity status:

Solid light

:

 pair is OK

Flashing light

pair is faulty 

No light

open pair

      a. Simultaneously, check the 5 vertically aligned LED 

indicators (SHORT, REVERSED, MISWIRE, SPLIT 
PAIRS) for the wiring faults.

      b. For more detailed information about what faults are 

occurring in which pairs, hold the TEST button for 2 
seconds to activate "Debug mode."  The tester will test 
each pair one by one, pausing briefly on each pair, and 
display the corresponding fault status.

LANtest Pro Tone Generator Operation (only 
available on models 256652/LBT, 256652/TK, 
256652/TFK and 256652/IDT):

 
   1. Slide the toggle switch on the LANtest Pro to the "Tone" 

position 

   2. Quickly press the TEST button once for continuous tone 

mode, or hold down for two full seconds for warble tone 

2

3

Summary of Contents for LANtest Pro 256652/LB

Page 1: ...B 256652 LBT 256652 IDT 256652 TK 256652 TFK User Manual Remote Network Cable Tester TM Pro LANtest LANtest Pro LANtest Pro withtone generator LANtest Pro withtone generator and4 remote IDs LANtest Pro with256712A Probe LANtest Pro with256712F Probe ...

Page 2: ...ally scanfor any existing faults in yourcable The speciallydesigned remote terminator is providedfor one person testingof installed cables The tonegenerator function canbe used tosend a signal through yourinstalled cables whichcan be tracedwith the Probe orany cable tracerin the market Package Contents For 256652 IDT 256652 LBT Users can buy 256712A or 256712F to Upgradethe tone function Item Numb...

Page 3: ... W x H Low battery indicator LANtest Pro Cable Test Operation 1 Select Cable positionon the toggleswitch 2 Plug one endof the subjectcable into theRJ45 jack on the master unitand the otherend into theRJ45 jack on the remote terminator Note The remote terminatorcan be slippedand locked intothe master unit forconvenient testing ofpatch cables 3 Push the test button and check the results First check ...

Page 4: ...level for various work environments Both amplifier and LED for loud or dark work environments Can work with any existing tone generator in the market Probe Specifications Pen style casing Special inductive plastic tip One push button TRACE switch One battery low LED indicator One amplifier and one LED for signal detection One rotary volume level switch Probe Operation 1 With the toggle switch on t...

Page 5: ...7 Short faults LED 8 Reversed faults LED 9 Miss wire faultsLED 10 Split pairs LED 11 Batterylow indicator 12 Test button 13 ON OFF switch 14 Battery cover 15 Remote unit 16 Remote test port RJ45 17 Tone indicator 1 Master port RJ45 2 Pair 1 indicator 3 Pair 2 indicator 4 Pair 3 indicator 5 Pair 4 indicator 6 Shield indicator 7 Short faults LED 8 Reversed faults LED 9 Miss wire faultsLED 10 Split p...

Page 6: ...4 3 1 2 1 2 1 2 3 6 4 5 7 8 SHIELD TEST LOW BATTERY SPLIT PAIRS SHORT REVERSED MISWIRE Low Battery Battery Replacement When the LOW BATTERY light illuminates the battery does not have sufficient power to support an accurate test At this time you must replace it with a new battery Battery Warning 1 Do not connect LANtest Pro to a live circuit as it may damage the tester and interfere with a live ne...