background image

                                               

                                             

If the cable’s pin out is different form the 

standard cable,

 

the beeper beeps “Bi—Bi—Bi--”, 

and LCD displays “Fail”

 

 
                                               

 

Fail! 

Length Test 

LANsmart Pro can measure the length of twisted cable, flat telephone line and coax 
line. 

Before test, user should setup the 

type

 of cable to be tested 

in the 

Configuration menu. 

For standard twisted cable, user should setup Configuration - “Cat5/Cat5e” or“Cat6” 
For non-standard twisted cable, flat telephone line and coax line, user should calibrate 
parameter by using a criterion cable first. It is operated by Configuration – Calibration 
menu  
 
Select Length from LANsmart Pro Main Menu 

 

 
 
 
 

            (Main Menu) 

Cable Test 

Length Test 

Identification 

Configuration

 

 

User should take off remote, or it will lead to 
inaccurate result. 

Please  

take off remote 

Yes 

 

 

 
 
 

 

Ntwk:   

93.8

        M 

Pairs Length    

 

First, LCD displays the average length.   
M for Meter, and Ft for Feet 
 
 
 
 
By selecting “Pairs Length” operation, user 
can see pair length. 

P1&2

              93.5 

P3&6

              92.1   

M

 

P4&5 

            94.0 

P7&8

              95.9             

 

 

 
 

 
 

 

Bulk cable length measurement 

 

 

9

Summary of Contents for LANsmart Pro

Page 1: ... Indicates the remote number of the remote identification unit for wire map test Incorporate Short Location function locate short position it determines if short is in the near or far end of the cable Measures twisted pairs of Cat5 Cat5E and Cat6 length without remote Measures length of flat 2 pin 4 pin and 6 pin telephone line Measures coax line length Self calibrating ability for non standard ca...

Page 2: ... range for cable length 0 300m 0 984 feet Split pairs detection minimum 1 2m 3 94 feet Analog Tone Generator 1 KHz Digital Tone Generator Single Tone and Double Tone Operating Temperature 0 C 50 C 32 F 122 F Storage Temperature 30 C 50 C 22 F 122 F Humidity 10 90 Weight Main unit 120g Remote unit 20g Dimensions Master 120 80 33mm Remote 44 42 28 5mm Power source DC 6V 4 AAA 2 ...

Page 3: ...ne line or coax line and calibrating parameters for non standard cable length test user must do the following configuration Follow the steps to configure the LANsmart Pro 1 Turn on the LANsmart Pro 2 LANsmart Pro will self diagnose first 3 Press the button to choose desired Configuration indicated by arrow SELECT Cable Test Length Test Identification Configuration Main Menu 4 Press the button and ...

Page 4: ... 5e Cat6 Ntwk Cal Tel Cal Coax Cal In order to increase measuring accuracy for cable length test the setup is used to adjust calibrating parameters for non standard cables It includes twisted cables flat phone lines and coax lines For example network cable calibration page explanation Ntwk Cal 10 M YES Ntwk the calibration object is network twisted pair Cal xx M It is the cable length supplied by ...

Page 5: ...Pro will begin to diagnose on the attached cable Cable Test Length Test Identification Configuration ENTER Wiremap Twisted Mapping Short Location Quick Test Diagnose ENTER Main Menu Cable test menu Transmitting side main unit 1 2 3 4 5 6 7 8 G 1 2 3 4 5 6 7 8 G Open Short Cross Idn Pass Split Rev Receiving side remote unit G Ground shield layer Idn The number of remote identification unit n 1 2 3 ...

Page 6: ...6 7 8 G 1 2 3 4 5 6 7 8 G Id3 Pass Pins are miswire 1 2 3 4 5 6 7 8 G 8 1 2 7 5 6 4 3 Id3 Fail LANsmart Pro can also identify and indicate the remote identification number attached to the far end of the subject cable The number of remote identification unit is 3 1 2 3 4 5 6 7 8 G 1 2 3 4 5 6 7 8 G Id3 Pass Twisted Mapping The cable s twisted status can be analyzed and shown as map by selecting the...

Page 7: ...s it will show the warning message Cannot detect cable under 1 2m Short Location LANsmart Pro can show which end of cable are shorted by using TDR technology Also user can see short details on Wiremap menu 1 Pair 1 1 2 are shorted at near side of cable TX 2 Pair 2 3 6 are shorted at far side of cable RX Short details display No pins are shorted Short details displa Wiremap Twisted Mapping Short Lo...

Page 8: ...then select Quick Test Wiremap Twisted Mapping Short Location Quick Test First record a cable s pin out as test standard User should connect the standard cable with the main unit and the remote unit Then select Record Cable Record Cable Test Cable When recording is completed the beeper Beeps Bi and the LCD display a message Cable Recorded Cable Recorded Then select Test Cable for mass cable testin...

Page 9: ...ndard twisted cable flat telephone line and coax line user should calibrate parameter by using a criterion cable first It is operated by Configuration Calibration menu Select Length from LANsmart Pro Main Menu Main Menu Cable Test Length Test Identification Configuration User should take off remote or it will lead to inaccurate result Please take off remote Yes Ntwk 93 8 M Pairs Length First LCD d...

Page 10: ...nd the tone signal The Selected pin will be highlighted Select to stop Tone mode and return to previous menu Note Under normal conditions Tone on all pins will be louder than Tone on single pin Select the Digital Tone options from Identification menu Select Single tone or Double Tone from Digital Tone Press ENTER to send Digital Tone Port Finder Port finder is a distinctive feature Professionals r...

Page 11: ...s all function module to stop working You must immediately turn off the unit Thank you for choosing Hobbes Corporation another innovation that is designed to improve trouble shooting network performance and productivity We are dedicated to providing the best quality and value for all your electronics needs Whether it s for individual corporate or governmental use Hobbes has the solution for you En...