OM-227 978 Page 15
5-4. Process/Polarity Table
Process
Polarity
Cable Connections
Cable To Gun
Cable To Work
GMAW
−
Solid wire with shield-
ing gas
DCEP
−
Reverse polarity
Connect to positive (+) out-
put terminal
Connect to negative (
−
) output
terminal
FCAW
−
Self-shielding wire
−
no shielding gas
DCEN
−
Straight Polarity
Connect to negative (
−
)
output terminal
Connect to positive (+) output
terminal
CHANGING
POLARITY
5-5. Changing Polarity
!
Turn off welding power
source.
1
Lead Connections For Direct
Current Electrode Negative
(DCEN)
2
Lead Connections For Direct
Current Electrode Positive
(DCEP)
Always read and follow wire
manufacturer’s recommended
polarity, and see Section 5-4.
Close door.
Ref. 209 228 / Ref. 209 229
1
2
DCEN
Electrode negative for
flux cored wire
DCEP
Electrode positive for
solid wire
Summary of Contents for Handler 210
Page 14: ...OM 227 978 Page 10 ...
Page 26: ...OM 227 978 Page 22 6 2 Weld Parameter Chart For 230 VAC Model ...
Page 27: ...OM 227 978 Page 23 227 949 B B ...
Page 33: ...OM 227 978 Page 29 Notes ...
Page 34: ...OM 227 978 Page 30 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram ...
Page 35: ...OM 227 978 Page 31 227 951 B ...
Page 46: ...OM 227 978 Page 42 Notes ...
Page 52: ...Notes ...
Page 54: ...Notes ...