OM-947 Page 17
5-6. Serial Number And Rating Label Location
The serial number and rating information for this product is located on back. Use rating label to determine input power requirements and/or rated output.
For future reference, write serial number in space provided on back cover of this manual.
5-7. Selecting A Location And Connecting Input Power For 115 VAC Model
1
Grounded Receptacle
A 115 volt, 20 ampere individual
branch circuit protected by time-de-
lay fuses or circuit breaker is re-
quired.
2
Plug From Unit
Select extension cord of 12 AWG
for up to 50 ft (15 m) or 10 AWG for
50 up to 100 ft (30 m).
!
Special installation may be
required where gasoline or
volatile liquids are present
−
see NEC Article 511 or CEC
Section 20.
803 443-C
!
Do not move or operate unit
where it could tip.
18 in.
(460 mm)
18 in.
(460 mm)
1
2