OM-926 Page 14
3-9.
Selecting A Location And Connecting Input Power
1
Rating Label
Supply correct input power.
2
Plug (NEMA Type 6-50P)
3
Receptacle
(NEMA Type 6-50R)
Connect plug to receptacle.
4
Input And Grounding
Conductors
For single-phase operation:
Y
Make input power
connections to the machine
before making connections
into a deenergized line
disconnect device. In the line
disconnect device, always
connect green or
green/yellow grounding
conductor to supply
grounding terminal first,
never to a line terminal.
Connect directly to line disconnect
device if hard wiring is required.
5
Line Disconnect Device
See Section 3-7.
Y
Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.
L1
L2
230 VAC, 1
18 in (457 mm) of
space for airflow
L1 (Black)
L2 (White)
Y
Do not move or operate unit
where it could tip.
Y
Always connect
grounding conductor first.
= GND/PE
3
2
5
4
208 959 / 803 222
Green Or
Green/Yellow
Install conductors into
a deenergized line
disconnect device.
U
0
U
2
I
2
X@40
Hz
pf =
S
1
U1=
U1=
I1 max=
I1 eff=
I1 max=
I1 eff=
S
SERIALNO.
STOCK NO.
LR 5 0 7 1
US
C
16.5A – 40A @ 140V
50%
260V
40A
140V
50/ 60
6.8KVA
208V
230V
1
.99
33A
30A
23A
21A
X35
1
—
—
—
—
—
—
—