OM-2226 / Operation and Maintenance Manual
60CU20 / Series 500062 / 400 Hz. Generator Set
May 2, 2013
Chapter 1-1
Page 21
(7) +5, -12 VDC Power Source (PS1)
Supplies the internal power distribution of +5 VDC and –12 VDC into the control system.
Figure 12: Control System Power Source
(8) Circuit Breakers (CB1, CB4, CB7)
Breaker
Number
Breaker
Name
Rating
(Amps)
System Protected
CB4
Engine
10
12 VDC engine electrical and fault circuits
CB7
Control
5
12 VDC control system
CB1
Marker Lights
10
12 VDC lighting system