OM-927 Page 15
3-10. Installing Wire Spool And Adjusting Hub Tension
When a slight force is needed
to turn spool, tension is set.
15/16 in
Use compression spring
with 8 in (200 mm) spools.
Tools Needed:
072573-B / 802 922
Installing 1 Or 2 lb Wire Spool
To install either a 1 lb or 2 lb wire
spool, follow the procedure as
shown in the illustration.
Remove these
components
from spindle.
Spindle
Spindle
Install these
components
onto spindle.
Order extra spring
Part No. 186 437
3-11. Changing Input Voltage
801 580-A
Y
Turn Off unit, and disconnect
input power.
Unit was shipped from factory set
for 230 volts.
1
Transformer T1
2
Rear Of Power Switch S1
3
Lead Marked 230 Volt And
Fan Motor Lead
Disconnect 230 volt lead and fan
motor lead from rear of S1. Leave
fan motor lead connected to 230
volt lead.
4
Lead Marked 200 Volt
Remove cable tie, and slide short
piece of sleeving off 200 volt lead,
and slide sleeving over end of 230
volt and fan motor leads. Fold
sleeving over and secure in place.
Connect 200 volt lead to S1 where
230 volt lead was removed.
Reinstall wrapper.