OM-203 653 Page 14
4-9. Installing Alternative Plug
1
Supplied 115 VAC Plug
Cut cord close to plug.
2
Alternative PLug (230 VAC
Plug Shown)
3
Load 1 (Brass) Terminal
4
Load 2 (Brass) Terminal
5
Ground (Green) Terminal
6
Outer Shell
7
Cord Grip
Strip cord jacket back enough to
separate conductors. Strip conduc-
tors enough to make good contact
with plug terminals. Make plug con-
nections and reinstall outer shell and
cord grip. Tighten assembly screws
onto shell. Do not overtighten.
Ref. 801 305-A / 801 611
This procedure is necessary if the unit is to be connected to a 230
VAC receptacle, or to a 115 VAC receptacle that requires a plug that
is different from the supplied plug.
Tools Needed:
1
6
7
2
3
4
5
See Section 4-8 for instructions on setting changeover switch for
proper voltage.