HV580L Series Frequency Inverter
66
Function
Code
Parameter Name
Setting Range
Default
Property
Group PB: Swing Frequency, Fixed Length and Count
Pb-00
Swing frequency setting mode
0: Relative to the central frequency
1: Relative to the maximum frequency
0
☆
Pb-01
Swing frequency amplitude
0.0%
~
100.0%
0.0%
☆
Pb-02
Jump frequency amplitude
0.0%
~
50.0%
0.0%
☆
Pb-03
Swing frequency cycle
0.1s
~
3000.0s
10.0s
☆
Pb-04
Triangular wave rising time
coefficient
0.1%
~
100.0%
50.0%
☆
Pb-05
Set length
0m
~
65535m
1000m
☆
Pb-06
Actual length
0m
~
65535m
0m
☆
Pb-07
Number of pulses per meter
0.1
~
6553.5
100.0
☆
Pb-08
Set count value
1
~
65535
1000
☆
Pb-09
Designated count value
1
~
65535
1000
☆
Group PC: Multi-Reference and Simple PLC Function
PC-00
Reference 0
-100.0%
~
100.0%
0.0%
☆
PC-01
Reference 1
-100.0%
~
100.0%
0.0%
☆
PC-02
Reference 2
-100.0%
~
100.0%
0.0%
☆
PC-03
Reference 3
-100.0%
~
100.0%
0.0%
☆
PC-04
Reference 4
-100.0%
~
100.0%
0.0%
☆
PC-05
Reference 5
-100.0%
~
100.0%
0.0%
☆
PC-06
Reference 6
-100.0%
~
100.0%
0.0%
☆
PC-07
Reference 7
-100.0%
~
100.0%
0.0%
☆
PC-08
Reference 8
-100.0%
~
100.0%
0.0%
☆
PC-09
Reference 9
-100.0%
~
100.0%
0.0%
☆
PC-10
Reference 10
-100.0%
~
100.0%
0.0%
☆
PC-11
Reference 11
-100.0%
~
100.0%
0.0%
☆
PC-12
Reference 12
-100.0%
~
100.0%
0.0%
☆
PC-13
Reference 13
-100.0%
~
100.0%
0.0%
☆
PC-14
Reference 14
-100.0%
~
100.0%
0.0%
☆
PC-15
Reference 15
-100.0%
~
100.0%
0.0%
☆