E1 communication defect
1. Connect wire loose or defect
1. Well connect the wire or change
the wire
2. Console defect
2. Change console
3. Controller defect
3. Change controller
E2 Motor defect
1. Motor connect wire or motor
defect
1. Change motor connect wire or
motor defect
E5 Overloading protect
1. The friction of running belt is too
big
1. Add silicone oil
2. Controller defect
2. Change controller
3. Motor defect
3. Change motor
E6 Explosion-proof rushed
1. Controller defect
1. Change controller
No heart rate display
1. The communication wire is not
connect well or defect
1. Connect the wire well or change
the wire
2. Main board defect
2. Change the console
3. When treadmill fold
3. Turn off power, lay flat the
running deck, turn on the power
E9 Ochrona złożenia
1. Controller defect
1. Change controller
2. Sensor or magnet defect
2. Change sensor or magnet defect
Incompleted information show
on console
1. The screw off console loose
1. Fasten the screw
2. Console defect
2. Change the console
Treadmill didn’t work
1. no power
1. Plug into socket
2. safety key isn’t in the right position
2. Replace the safety key
3. broken circuit signal system
3. Check the controller input and
signal wire
4. switch off
4. Place the power switch in the
“NO”position.
5. fuse burnt out
5. Change the fuse
The running belt does not run
smoothly
1. no enough lubrication
1. Use the Silicone oil
2. running belt too tight
2. Adjust the tightness of running
belt
Running belt slips
1. running belt too loose
1. Adjust the tightness of running
belt
2. motor belt too loose
2. Adjust the tightness of motor belt
The keys malfunction
1. broken keys
a. Change the key board and wire
b. Change the mainboard
c. Change the console
Stop abruptly under normal
state
1. Safety key drop out
1. Replace the safety key
2. broken system
2. Ask serviceman to repair it