17 (36)
Fig. 13
Save application
►
In window
Add/Remove application
save the configuration with button
Save
(
1
).
►
In field
Control
(
2
) define the memory the configuration is downloaded to:
–
Select Flash for the non-volatile memory of the target device. Configurations which are
downloaded to the Flash memory, are automatically started at the next power-on of
the device.
–
Select RAM for the volatile memory of the target device. Configurations which are
installed in the RAM memory are lost when the device is switched off.
►
To start the configuration on the CANnector Log, click button
Download/Start
(
3
).
CANnector Log User Manual
4.01.0091.21000 1.1 en-US